Command Directory
3-4 Commands
MG369xC GPIB PM
PN: 10370-10374 Rev. F
3-49
KH
Description:
kHz data terminator.
Functional
Category:
DATA TERMINATOR
Front Panel Key:
N/A
KV
Description:
kHz per volt (kHz/V) data terminator.
Functional
Category:
DATA TERMINATOR
Front Panel Key:
N/A
L0 or L0 <value> <unit>
Description:
Sets RF output power level to L0. Opens L0 parameter.
Causes the RF output power level to be set to the preset (or previously set) L0 power
level. Also permits setting the L0 parameter. The power level setting is determined by
the power level range of the particular MG369xC model.
Functional
Category:
POWER LEVELING
Value:
Power level range of the MG369xC model
Units:
DM (log), VT (linear)
Example:
L0 5 DM
Places the RF output power level at the preset (or previously set) L0 power level and
opens the L0 parameter for data entry. Sets the L0 power level to 5 dBm.
Output Command:
OL0
returns the L0 power level (in dBm when in log mode; in mV when in linear mode)
to the controller.
Related
Commands:
LOG
,
LIN
,
PU0
,
PU1
,
PU2
Front Panel Key:
Level
|
Level
|
Level Control >
| L0
L1 or L1 <value> <unit>
Description:
Sets RF output power level to L1. Opens L1 parameter.
Causes the RF output power level to be set to the preset (or previously set) L1 power
level. Also permits setting the L1 parameter. The power level setting is determined by
the power level range of the particular MG369xC model.
Functional
Category:
POWER LEVELING
Value:
Power level range of the MG369xC model
Units:
DM (log), VT (linear)
Output Command:
OL1
returns the L1 power level (in dBm when in log mode; in mV when in linear mode)
to the controller.
Related
Commands:
LOG
,
LIN
,
PU0
,
PU1
,
PU2
Front Panel Key:
Level
|
Level
|
Level Control >
|
L1