MG369xC GPIB PM
PN: 10370-10374 Rev. F
3-1
Chapter 3 — Command Directory
3-1
Introduction
This chapter provides alphabetically-ordered listings and descriptions of all MG369xC GPIB programming
commands.
3-2
Typographic Conventions
The typographic conventions, abbreviations, and syntax legend used throughout this chapter to define the
GPIB commands are described in
.
3-3
Functional Categories
The MG369xC’s GPIB functional categories are described in
; they provide descriptive details and
tabular data that apply to the category as a whole.
3-4
Commands
The remaining pages in this chapter provide an alphabetical listing of the GPIB commands used to program
the series MG369xC Synthesized Signal Generator.
Figure 3-1.
Typographic Conventions for the GPIB Command Listings
ASD <value> <unit>
Description:
Opens the external AM dB/V sensitivity parameter.
Functional
Category:
PARAMETER ENTRY
Value:
0 dB/V to 25 dB/V
Units:
DV
Example:
AM2 ASD 3 DV
Turns on external log AM with a sensitivity of 3 dB/Volt.
Output Command:
OAB
Related
Commands:
AM2
Front Panel Key:
Modulation
|
AM
(external) |
Edit Sensitivity
Command Function
Command’s Functional
Category
Command Syntax
Allowable values and
units for the Command
Argument
Additional
description
fields