Configuring Communication
73
7" Modero Touch Panels
3.
Press the
Master IP/URL
field to open a Keyboard and enter the Master IP Address
(obtained from
the Diagnostics - Networking Address dialog
of the NetLinx Studio application)
.
4.
Click
Done
to accept the new value and return to the System Settings page.
5.
Do not alter the Master Port Number value (
this is the default value used by NetLinx
).
6.
Enter a username and password (
into their respective fields
) if the target Master has been previously
secured.
7.
Press the
Back
button to open the Protected Setup page.
8.
Press the on-screen
Reboot
button to both save any changes and restart the panel.
Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode
In this mode, you must add the Modero panel IP Address into the URL List of the Master (using NetLinx
Studio). This mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP
from its URL list).
1.
Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP
Address from the IP Settings of the System Settings page.
The
DHCP/Static
field (in the IP Settings section of the System Settings page) must be set to
DHCP
to get Dynamic IP information for the panel.
Press the on-screen
Reboot
(from the Protected Setup page) to both save any changes and
restart the panel.
After power-up, press the grey Front Setup Access button for
3 seconds
to access the Setup
page.
Navigate to the
Setup > Protected Setup > System Settings
page and note the newly
obtained Dynamic IP Address information from the IP Settings section. This information is
then entered into the URL List for the connected NetLinx Master.
2.
Toggle the
Type
field until
Ethernet
is selected (
from the Master Connection section of the System
Settings page
).
3.
Press the
Mode
field (to set the connection Mode) until the choice cycles to the word
Listen
.
The System Number and Master IP/URL fields are then greyed-out.
4.
Enter a username and password (
into their respective fields
) if the target Master has been previously
secured.
5.
Select the
OnLine Tree
tab from the Workspace window.
6.
Select
Diagnostics
>
URL Listing
from the Main menu (FIG. 71).
7.
Enter the
System
and
Device
number for the specific Master associated with your panel (
as seen in
the OnLine Tree tab
).
8.
Click
Add
and enter the IP Address of the Modero touch panel into the
Add URL
dialog.
9.
Click
OK
to enter your IP Address and add it to the list.
10.
Click
Done
once you are finished adding your panel information to the list.
11.
Press the on-screen
Reboot
button to save any changes and restart the panel.
If the panel does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number (from
within the Device Addressing dialog) is correctly assigned.
Содержание Modero CV7
Страница 1: ...Operation Reference Guide Touch Panels NXD T CV7 7 Modero Touch Panel Last Revised 10 19 2011...
Страница 42: ...CV7 Touch Panel Accessories 30 7 Modero Touch Panels...
Страница 58: ...Installation 46 7 Modero Touch Panels...
Страница 194: ...Programming 182 7 Modero Touch Panels...
Страница 200: ...Appendix A 188 7 Modero Touch Panels...
Страница 211: ...Appendix B Wireless Technology 199 7 Modero Touch Panels...
Страница 212: ...Appendix B Wireless Technology 200 7 Modero Touch Panels...
Страница 218: ...Troubleshooting 206 7 Modero Touch Panels...
Страница 219: ...Troubleshooting 207 7 Modero Touch Panels...