20
Installing Mini-Touch Panels
Color Active-Matrix LCD Mini-Touch Panels
1
2
3
4
1 - GND (-)
3 - AXP
2 - AXM
4 - PWR (+)
4-pin mini-XLR
connector
PWR (+)
Control system
GND (-)
2
1
PWR (+)
AXM
AXP
3
4
GND (-)
12 VDC power supply
Using the AXlink connector for data and power
Connect the Central Controller’s AXlink connector to the AXlink connector (male) on
the rear panel of the touch panel for data and 12 VDC power as shown in Figure
23.
PWR (+)
AXM
AXP
GND (-)
UniMount or rack-mount
AXlink connector
Central Controller
PWR (+)
AXM
AXP
GND (-)
Using the AXlink four-pin connector and external 12 VDC power supply
Connect the Central Controller’s AXlink connector to the AXlink connector on the
rear panel of the touch panel as shown in Figure 24.
Figure 22
Mini-XLR connector to exter-
nal 12 VDC power supply,
and Central Controller wiring
diagram
Figure 23
AXlink wiring diagram
Caution
If you are using power from
AXlink, disconnect the wiring
from the Central Controller
before wiring the touch panel.