Troubleshooting
63
DGX Transmitters & Receivers Instruction Manual
Live Status Update Messages
Live status update messages will appear at times in a terminal emulation program (e.g., TeraTerm,
PuTTY, or HyperTerminal) when a module is connected to a PC via the USB port (see page 67). These
messages can be helpful for technical support when assessing the state of the system.
Certain activity/conditions in the system can trigger live status update messages. The majority of the
messages simply verify normal responses/changes in the state of the system and are not a cause for
concern. However, if you are having problems, have tried the strategies in the Troubleshooting Flow
Charts, and reached the point where you need to contact technical support, technical support may ask
you to take certain actions with the system and provide them with the resulting live status update
messages.
Note:
None of the live status update messages have error codes that are directly associated with
them.
Example of a Typical Live Status Update Message
The following example is taken from a DGX HD-15 TX Module when a valid video signal is applied
and the system is responding correctly.
FIG. 39
Example of live status update message on DGX HD-15 TX Module
Video Signal Change
valid sync present
valid video detected
match in the lookup table
apply selected format, FID = 5630
laser ON
Содержание AVB-RX-DGX-SC Fiber-DVI
Страница 10: ...Notices 6 DGX Transmitters Receivers Instruction Manual ...
Страница 54: ...Adjusting Video with BoardConfig Software 50 DGX Transmitters Receivers Instruction Manual ...
Страница 60: ...EDID Programmer 56 DGX Transmitters Receivers Instruction Manual ...
Страница 70: ...Troubleshooting 66 DGX Transmitters Receivers Instruction Manual ...
Страница 76: ...Appendix B Restoring Default Settings 72 DGX Transmitters Receivers Instruction Manual ...