Installation and Setup
29
DGX Transmitters & Receivers Instruction Manual
Basic Installation
Installation Scenario 1 (Basic) Automatic Image Adjustment and Automatic EDID Scaling
The flow chart in FIG. 21 assumes that the results from the automatic image adjustment and automatic
EDID scaling require no further adjustment.
For most installations, the following basic installation steps will provide a satisfactory image on the
destination device. If the installation has special requirements, three additional scenarios are presented at
the end of the basic installation steps which indicate how to handle them. Depending on the installation’s
requirements, one or more of the three scenarios could apply.
Safety Recommendations for Laser Products
Important:
There are no user serviceable parts inside AMX DGX SC Fiber products; service should
only be done by qualified personnel.
Caution
- Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
Exercise caution when installing DGX products to avoid direct eye exposure to invisible laser radiation.
Follow the recommendations below whenever installing or working with DGX products.
Be sure to apply the power last, so that the fiber connector is
not
exposed when power is
applied.
Do
not
remove dust plugs from SC fiber connectors or the dust caps from the fiber cables until
establishing connections; avoid direct eye exposure.
Make sure all cables, including fiber cables, are correctly connected and/or terminated.
If you need to unplug the fiber cable, be sure to unplug the power on the TX first.
TX – Attaching Signal Cables
Check When Fastening Fiber Cable:
Make sure that no dust or debris are on the exposed ends of the fiber cable.
Make sure that the fiber cable connectors seat firmly into the module’s fiber connector.
Normally an audible click is heard when a connector engages.
Caution:
Do not severely bend or kink the fiber cable. It can cause irreversible damage to the cable.
The bend radius for AMX fiber cables is 2 inches (5 cm).
Note:
If an interlaced video format is sent to a TX, the RX will output a progressive video format,
regardless of the scaling mode.
FIG. 21
Basic installation procedure – assumes image is satisfactory
Set the A/B
Sync Set switch
Attach
connectors
Apply power
TX
Attach
connectors
Apply power
RX
Basic Installation
DGX HD-15 TX only
Содержание AVB-RX-DGX-SC Fiber-DVI
Страница 10: ...Notices 6 DGX Transmitters Receivers Instruction Manual ...
Страница 54: ...Adjusting Video with BoardConfig Software 50 DGX Transmitters Receivers Instruction Manual ...
Страница 60: ...EDID Programmer 56 DGX Transmitters Receivers Instruction Manual ...
Страница 70: ...Troubleshooting 66 DGX Transmitters Receivers Instruction Manual ...
Страница 76: ...Appendix B Restoring Default Settings 72 DGX Transmitters Receivers Instruction Manual ...