Site Recommendations
When placing the modules, follow the recommendations and precautions in this section to reduce potential
installation and operation hazards.
Environment
Choose a clean, dust free, (preferably) air-conditioned location.
Avoid areas with direct sunlight, heat sources, or high levels of EMI
(Electromagnetic Interference).
Module Accessibility
Make sure the front of each module is accessible, so that you can monitor the LED indicators. Leaving
adequate clearance at the rear will also allow for easier cabling and service.
Power
The source’s electrical outlet should be installed near the modules, easily accessible, and properly grounded.
Power should come from a building branch circuit. To avoid an overload, note the power consumption rating
of all the equipment connected to the circuit breaker before applying power.
General Hazard Precautions
These recommendations address potential hazards that are common to all installations:
Elevated Operating Temperature
The maximum rated ambient temperature for DGX Fiber modules is 113° F (45° C).
All equipment should be installed in an environment compatible with the manufacturer’s maximum rated
ambient temperature. In a closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than the ambient room temperature.
Caution:
To protect the equipment from overheating, do not operate in an area that exceeds
113° F (45° C) and follow the clearance recommendation below for adequate airflow.
Airflow Restriction
The modules are designed to adequately dissipate the heat they produce under normal operating conditions;
however, this design is defeated when high heat producing equipment is placed directly above or below a
module.
Caution:
To prevent overheating, avoid placing high heat producing equipment directly above or below
the modules. We recommend
allowing one empty rack unit of clearance above the vent holes on top of
the modules.
Reliable Earthing (Grounding)
Reliable earthing of rack-mounted equipment should be maintained. If not using a direct connection
to the branch circuit (e.g., plugging into a power strip), pay particular attention to supply connections.
Содержание AVB-RX-DGX-SC Fiber-DVI
Страница 10: ...Notices 6 DGX Transmitters Receivers Instruction Manual ...
Страница 54: ...Adjusting Video with BoardConfig Software 50 DGX Transmitters Receivers Instruction Manual ...
Страница 60: ...EDID Programmer 56 DGX Transmitters Receivers Instruction Manual ...
Страница 70: ...Troubleshooting 66 DGX Transmitters Receivers Instruction Manual ...
Страница 76: ...Appendix B Restoring Default Settings 72 DGX Transmitters Receivers Instruction Manual ...