![AMS EPIC SENSIT 3 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/ams/epic-sensit-3/epic-sensit-3_operation-and-service-manual_2936148038.webp)
L0190D
32
OUT OF SERVICE MESSAGE
Certain critical errors will disable the vendor. When this
happens, an “OUT OF SERVICE” message will be displayed.
To get the vendor back in service, press the mode switch on the
control board. Any errors will be displayed immediately. Refer to
the list of error codes and explanations below.
Correct the cause
of the error first,
then press “
0
” to clear the error code. Certain
errors will have more detail available: press
1
to see more
detailed (sublevel) error codes, or
2
for date/time of last
occurrence.
ERROR CODES: CAUSES AND SOLUTIONS
Viewing Top Level Error Codes
To view top level error codes, enter the service mode by
pressing the mode switch located at the lower right corner of the
control board.
ACCOUNTING DATA
will be displayed if there
are no errors or an error has been cleared (whether corrected or
not). If the error message has been cleared, but the cause has
not been corrected, the message can be re-displayed by briefly
turning off the power. Use the keypad buttons to perform the
following:
# - NEXT ERROR
– to view the next top level error
code in memory.
2 - DETAILS
– displays the time and date of last error
occurrence.
1 - SUBLVL ERRORS
– to display any sublevel error
codes including MDB devices.
0 - CLEAR ERROR
– to erase the error code from
memory (first correct the error).
Viewing Sub-Level Error Codes
To view the sub-level error codes, press the 1 key while the top
level error code is being displayed.
Correct the condition which
caused the error first, then clear the error code by pressing “0”.
Once all errors are cleared,
ACCOUNTING DATA
will be
displayed.
CLEARING JAMMED MOTOR
If one or more motors and helices become jammed, the motors
will be displayed as a sublevel error under “Motor Jammed”.
Energized vend motors can turn a helix with considerable
torque, creating a possible entrapment hazard. Disconnect
power to the vendor or control board before freeing a
jammed helix or motor.
Always restrain or block the helix
before freeing a jammed or caught product.
CAUTION
:
Use caution when freeing jammed product
Clear any jammed products from the indicated vend columns.
To reset the error, first enter service mode, then select Tray
Setup (See
TRAY SETUP
on page 23). Press “
1
”, then “
*
”, then
“
3
”. The control will attempt to run the jammed motors. If the
motor had been taken out of the motor matrix, it will be
re-established in the matrix.
7
TROUBLESHOOTING
Содержание EPIC SENSIT 3
Страница 12: ...L0190D 6 THIS PAGE INTENTIONALY LEFT BLANK ...
Страница 18: ...L0190D 12 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 26: ...L0190D 20 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...L0190D 38 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 45: ...L0190D 39 Epic Model 9 WIRING DIAGRAM Note Transformer part numbers are forma ed as 120 V 220V ...
Страница 46: ...L0190D 40 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 50: ...L0190D 44 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 52: ...L0190D 46 THIS PAGE INTENTIONALLY LEFT BLANK ...