Temposonics
®
R-Series
V
POWERLINK
Operation Manual
I 6 I
3.2 Order code of Temposonics
®
RH5
a
Sensor model
R
H 5
Rod
b
Design
B
Base unit (only for replacement)
J
Threaded fl ange M22×1.5-6g (rod Ø 12.7 mm),
stroke length: 25…5900 mm (1…232 in.)
M
Threaded fl ange M18×1.5-6g (standard)
S
Threaded fl ange ¾"-16 UNF-3A (standard)
T
Threaded fl ange ¾"-16 UNF-3A (with raised-face)
c
Mechanical options
A
Standard
B
Bushing on rod end (only for design
»
M
«
,
»
S
«
&
»
T
«
)
M
Thread M4 at rod end (only for design
»
M
«
,
»
S
«
&
»
T
«
)
V
Fluorelastomer seals for the sensor electronics housing
d
Stroke length
X X X X M
0025…7620 mm
Standard stroke length (mm)
Ordering steps
25… 500 mm
5 mm
500… 750 mm
10 mm
750…1000 mm
25 mm
1000…2500 mm
50 mm
2500…5000 mm
100 mm
5000…7620 mm
250 mm
X X X X U
001.0…300.0 in.
Standard stroke length (in.)
Ordering steps
1… 20 in.
0.2 in.
20… 30 in.
0.4 in.
30… 40 in.
1.0 in.
40…100 in.
2.0 in.
100…200 in.
4.0 in.
200…300 in.
10.0 in.
Non-standard stroke lengths are available;
must be encoded in 5 mm/0.1 in. increments.
.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
R
H 5
D 5
1
U 3
1
a
b
c
d
e
f
g
h
NOTICE
• Specify the number of magnets for your application and order the
magnets separately.
• The number of magnets is limited by the stroke length.
The minimum allowed distance between magnets (i.e. front face
of one to the front face of the next one) is 75 mm (3 in.).
• Use magnets of the same type for multi-position measurement.
• If the option for internal linearization (U311) in
h
“Output” is
chosen, select a suitable magnet.
e
Number of magnets
X X
01…30 position(s) (1…30 magnet(s))
f
Connection type
D 5 6
2 × M12 female connectors (D-coded),
1 × M8 male connector
D 5 8
2 × M12 female connectors (D-coded),
1 × M12 male connector (A-coded)
g System
1
Standard
h Output
U 3 0 1
POWERLINK, position and velocity
(1…30 magnet(s))
U 3 1 1
POWERLINK, position and velocity,
internal linearization (1…30 magnet(s))