Temposonics
®
R-Series
V
POWERLINK
Operation Manual
I 52 I
Index Subindex
Name
Object type
Attribute
Data type
Description
2201
Number of magnets
Variable
rw
Unsigned8
Setting the number of position magnets that are used simultaneously on
the measuring rod/profile
Note: If the number is greater than in the order code, an alarm is issued.
2202
Filter settings
Array
Setting the filter for the output value
0
Number of entries
Variable
ro
Unsigned8
1
Filter type
Variable
rw
Unsigned8
Setting the filter for the output value
•
Bit value 0: No filter
•
Bit value 1: FIR (finite impulse response filter)
•
Bit value 2: IIR (infinite impulse response filter)
2
Filter window size
Variable
rw
Unsigned8
Setting the number of position values for calculating the filter of the
output value
Possible values: 2…16
3
Velocity window size
Variable
rw
Unsigned8
Setting the number of position values for determining the velocity of the
position magnet
Possible values: 2…16
2203
Position offsets
Array
Position offset for up to 30 magnets
0
Number of entries
Variable
ro
Unsigned8
1…30
Position offset for magnets 1…30
Variable
rw
Integer32
2204
Lower limit for measurement
cycle time
Variable
rw
Unsigned32
Setting the lower limit for the cycle time. If no short cycle time is required,
reflections can be excluded with this parameter
2305
Sensor status
0
Number of entries
Variable
ro
Unsigned8
1
Time since last update
Variable
ro
Integer32
Age of the status data in ms
2
Status data version
Variable
ro
Integer32
Version number
3
Operational time
Variable
ro
Integer32
Total operational time of the sensor
4
Odometer
Variable
ro
Integer32
Total distance travelled by the position magnet
5
Magnet cycles
Variable
ro
Integer32
Total number of directional changes of the magnet
6
Minimum input voltage
Variable
ro
Integer32
Minimum input voltage so far
7
Maximum input voltage
Variable
ro
Integer32
Maximum input voltage so far
8
Minimum temperature
Variable
ro
Integer32
Minimum temperature inside sensor electronics housing so far
9
Maximum temperature
Variable
ro
Integer32
Maximum temperature inside sensor electronics housing so far
10
Current temperature
Variable
ro
Integer32
Current temperature inside sensor electronics housing
11
Input voltage out of range
Variable
ro
Integer32
Duration of exceeding or falling below the permissible power supply range
12
Temperature out of range
Variable
ro
Integer32
Duration of exceeding or falling below the permissible operating
temperature range
6000
Operating parameters
rw
Unsigned16
6002
Total measuring range
in measuring units
Variable
rw
Unsigned32
If the scaling function is activated (see object 6000: Operating parameters),
this parameter includes the maximum value
6005
Linear encoder measuring
step settings
Array
1
Position step setting
Variable
rw
Unsigned32
Resolution of the position output in nm
2
Speed step setting
Variable
rw
Unsigned32
Resolution of the velocity output in 0.01 mm/s
Table 2: Index 2201, 2202, 2203, 2204, 2305, 6000, 6002, 6005
The parameters of the group “Device Specific Parameters”: