I 27 I
4.7 Alignment of the magnet with the option
“Internal linearization”
The internal linearization offers improved linearity of the sensor.
The option must be specified in the order code of the sensor.
The internal linearization is set for the sensor during production.
A sensor with internal linearization is delivered with the magnet with
which the sensor was squared during production. In order to achieve
the best possible result, Temposonics recommends to operate the
sensor with the supplied magnet.
For the internal linearization, the following magnets can be used:
• Ring magnet OD33 (part no. 253 620), for RH5 & RDV only
• U-magnet OD33 (part no. 254 226)
• Ring magnet OD25.4 (part no. 253 621), for RH5 & RDV only
• Magnet slider S (part no. 252 182), for RP5 only
• Magnet slider N (part no. 252 183), for RP5 only
• Magnet slider V (part no. 252 184), for RP5 only
• Magnet slider G (part no. 253 421), for RP5 only
The ring magnet and U-magnet will be marked for the internal
linearization. During the installation, the magnets have to be aligned to
the sensor electronics housing or the flange of the RDV (see Fig. 41,
Fig. 42, Fig. 43 and Fig. 44).
For RH5 POWERLINK sensors with ring magnet/U-magnet applies:
• Install the magnet until the marking on the magnet points to the
sensor electronics housing.
• The marking on the magnet points to the same direction as the
elongated status LED in the lid of the sensor electronics housing.
Fig. 41: Magnet alignment of ring magnet for RH5 POWERLINK with internal linearization
For RP5 POWERLINK sensors with U-magnet applies:
• Install the magnet until the marking on the magnet points to the
sensor electronics housing.
• The marking on the magnet points to the same direction as the
elongated status LED in the lid of the sensor electronics housing.
Fig. 42: Magnet alignment of U-magnet for RP5 POWERLINK with internal linearization
Fig. 43: Magnet alignment of magnet slider for RP5 POWERLINK with internal linearization
Marking
Elongated status LED
Marking
Elongated status LED
1
2
Additional borehole
Joint
For RP5 POWERLINK sensors with magnet slider applies:
•
1
Install the magnet sliders "S", "N" and "G" until the additional hole
in the magnet points towards the sensor electronics housing.
•
2
Install the magnet slider "V" until the joint points to the end of the
profile.