10.4 Technical data Temposonics
®
RDV
Temposonics
®
R-Series
V
POWERLINK
Operation Manual
Output
Interface
Ethernet POWERLINK
Data protocol
POWERLINK V2
Measured value
Position, velocity/option: Simultaneous multi-position and multi-velocity measurements up to 30 magnets
Measurement parameters
Resolution: Position
0.5…100 µm (selectable)
Cycle time
Stroke length
≤ 50 mm
≤ 715 mm
≤ 2000 mm
≤ 4675 mm
5080 mm
Cycle time
250 µs
11
500 µs
1000 µs
2000 µs
3200 µs
Linearity deviation
12, 13
Stroke length
≤ 500 mm
> 500 mm
Linearity deviation
≤ ± 50 µm
< 0.01 % F.S.
Optional internal linearization: Linearity tolerance (applies for the first magnet for multi-position measurement)
Stroke length 25…300 mm 300…600 mm 600…1200 mm
typical
± 15 µm
± 20 µm
± 25 µm
maximum
± 25 µm
± 30 µm
± 50 µm
Repeatability
< ±0.001 % F.S. (minimum ±2.5 μm) typical
Hysteresis
< 4 µm typical
Temperature coefficient
< 15 ppm/K typical
Operating conditions
Operating temperature
−40…+85 °C (−40…+185 °F)
Humidity
90 % relative humidity, no condensation
Ingress protection
Sensor electronics IP67 (with professional mounted housing and connectors)
Measuring rod with connecting cable for side cable entry IP65
Measuring rod with single wires and flat connector with bottom cable entry IP30
Shock test
100 g/11 ms, IEC standard 60068-2-27
Vibration test
10 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test
Electromagnetic emission according to EN 61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The RDV sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 No. 1091 and
TR CU 020/2011 under the condition of an EMC-compliant installation.
14
Operating pressure
350 bar (5076 psi)/700 bar (10,153 psi) peak (at 10 × 1 min) for sensor rod
Magnet movement velocity Any
Design/Material
Sensor electronics housing Aluminum (painted), zinc die cast
Sensor rod with flange
Stainless steel 1.4301 (AISI 304)
RoHS compliance
The used materials are compliant with the requirements of EU directive 2011/65/EU and EU regulation
2015/863 as well as UKSI 2022 No. 622
Stroke length
25…2540 mm (1…100 in.) for pressure-fit flange »S«
25…5080 mm (1…200 in.) for all threaded flanges
Mechanical mounting
Mounting position
Any
Mounting instruction
Please consult the technical drawings on
and on
Electrical connection
Connection type
2 × M12 female connectors (5 pin), 1 × M8 male connector (4 pin)
2 × M12 female connectors (5 pin), 1 × M12 male connector (4 pin)
Operating voltage
+12…30 VDC ±20 % (9.6…36 VDC)
Power consumption
Less than 4 W typical
Dielectric strength
500 VDC (DC ground to machine ground)
Polarity protection
Up to −36 VDC
Overvoltage protection
Up to 36 VDC
11/
Minimum cycle time for multi-position measurements (number of magnets ≥ 2): 400 µs
12/
With position magnet # 251 416-2
13/
For rod style »S« the linearity deviation can be higher in the first 30 mm (1.2 in.) of stroke length
14/
The cable between the sensor element and the electronic housing must be mounted in an appropriately shielded environment.