of the particular parameter (e.g. '3.5', 'state is on-hook', etc),
<unit> - is the human readable representation of the unit describing
the <value>.
If there are several parameters constituting the result of the individual
test, then all values will be presented in the following format:
[P=<param-1>,V=<value-1>,U=<unit-1>][P=<param-2>,V=<value-2>,U=<unit
-2>].....
If the test is not represented by the measurable value, or the test has
not been complete for any reason, then the object must contain zero-length
string.
2.2.10 Audible Tone Tables
Audible tone tables can be used to configure the settings for each audible tone
for service interruptions or UPS battery conditions. Whether these tones are
played is controlled by the MIB emtaSignalingAnnouncementCtrl, and the
settings for the tones can be configured by the MIBs within the
emtaSignalingDevToneTable and the emtaSignalingDevMultiFreqToneTable.
The emtaSignalingDevToneTable is indexed by tone type, which is the
pre-defined service interruptions of “RF Loss”, “Endpoint Disabled”, and
“Endpoint Disconnected”, and the pre-defined UPS battery condition of “Loss of
AC Power”, “Low Battery”, “Bad Battery”, and “Battery Over Temp”. The
emtaSignalingDevMultiFreqToneTable is indexed by tone type and a frequency
number.
brcm-emta-mgmt.mib
MIB
Default Value
Access
emtaSignalingAnnouncementCtrl
BITS (000)
read-write
emtaSignalingDevToneWholeToneRepeatCount
-
read
emtaSignalingDevToneSteady
-
read
emtaSignalingDevToneFirstFreqValue
-
read
emtaSignalingDevToneSecondFreqValue
-
read
emtaSignalingDevToneDbLevel
-
read
emtaSignalingDevToneFreqOnDuration
-
read
emtaSignalingDevToneOffDuration
-
read
emtaSignalingDevToneFreqRepeatCount
-
read
Содержание U10C034
Страница 1: ...U10C034 Telephony MSO User s Manual Version 1 4 Date Aug 2008 ...
Страница 2: ...U10C034 Telephony Version v1 4 June 2008 ii ...
Страница 4: ...U10C034 Telephony Version v1 4 June 2008 iv ...
Страница 17: ...U10C034 MSO User s Manual v1 4 June 2008 17 ...
Страница 19: ...U10C034 MSO User s Manual v1 4 June 2008 19 brcm cm mgmt mib Broadcom eMTA Proprietary MIBS brcm emta mgmt mib ...
Страница 54: ...U10C034 Telephony Version v1 4 June 2008 54 3 4 CM Hardware ...
Страница 55: ...55 3 5 Event Log ...
Страница 56: ...U10C034 Telephony Version v1 4 June 2008 56 3 6 CM State ...
Страница 58: ...U10C034 Telephony Version v1 4 June 2008 58 3 8 Product Display status interface information ...
Страница 59: ...59 3 9 DHCP Display CM and MTA DHCP information ...
Страница 60: ...U10C034 Telephony Version v1 4 June 2008 60 3 10 MTA Display some detail MTA parameters ...
Страница 61: ...61 3 11 QoS Display service flow information ...
Страница 62: ...U10C034 Telephony Version v1 4 June 2008 62 3 12 Config Params Display CM and MTA config files information ...
Страница 63: ...63 3 13 Event Log Display CM and MTA event logs ...
Страница 89: ...89 7 Appendix A eMTA LED Behavior This section describes a matrix details the U10C034 LED behavior ...
Страница 90: ...U10C034 Telephony Version v1 4 June 2008 90 U10C034 Telephony MSO User s Manual ...