U10C034 Telephony Version v1.4 June 2008
38
emtaSignalingEndptCtrlToneDetectionControl
AlarmPOSDisabled(4)
read-write
emtaSignalingPowerRingFrequency
f20Hz(1),
read
emtaSignalingRingWaveform
Sinusoidal(1)
read-write
emtaRingWithDCOffset
(1.3.6.1.4.1.4413.2.2.2.1.6.1.3.0 Integer32)
This object specifies whether the ring with DC offset option is enabled.
emtaSignalingEndptCtrlAnalogLoopback
(1.3.6.1.4.1.4413.2.2.2.1.6.4.1.1.1.x Integer32)
This object controls the implementation of the analog loopback by the
MTA. When the object is set to true(1), the MTA MUST implement analog
loopback operations. When the object is set to false(2), the MTA MUST
stop loopback operations immediately. The default value of this object
corresponds to the functionality compliant with the PacketCable
requirements.
emtaSignalingEndptCtrlLineReset
(1.3.6.1.4.1.4413.2.2.2.1.6.4.1.1.2.x Integer32)
This object controls the resetting the telephone line. Setting this object
to true(1) causes the eMTA to reset the telephone line of the corresponding
endpoint. Setting this object to false(2) does not have any affect. Reading
this object always returns 'false(2)'.
emtaSignalingEndptCtrlBoostedLoopCurrent
(1.3.6.1.4.1.4413.2.2.2.1.6.4.1.1.8.x Integer32)
This object indicates whether the loop current should be boosted (true(1))
or not (false(2)). The particular value for the loop current depends on
the particular hardware (SLIC) being used.
emtaSignalingEndptCtrlTxGain
(1.3.6.1.4.1.4413.2.2.2.1.6.4.1.1.9.x Integer32)
This Object represents the per line transmitter (A/D) gain. A positive
number reflects a signal gain; a negative number reflects a signal loss.
This Object does not reflect the desired level at the Telco (POTS) a-b
(T/R) terminals as it does not include the affects of the gain settings
on the analog interfaces which are pre-configured for a given country
specification.
The
gain
setting
specified
in
this
MIB
object
will
be
applied
on top of the preconfigured settings and therefore represents a relative
level, while ambitTxGain will overwrite the preconfigured settings and
represents a absolute level.
emtaSignalingEndptCtrlRxGain
(1.3.6.1.4.1.4413.2.2.2.1.6.4.1.1.10.x Integer32)
Содержание U10C034
Страница 1: ...U10C034 Telephony MSO User s Manual Version 1 4 Date Aug 2008 ...
Страница 2: ...U10C034 Telephony Version v1 4 June 2008 ii ...
Страница 4: ...U10C034 Telephony Version v1 4 June 2008 iv ...
Страница 17: ...U10C034 MSO User s Manual v1 4 June 2008 17 ...
Страница 19: ...U10C034 MSO User s Manual v1 4 June 2008 19 brcm cm mgmt mib Broadcom eMTA Proprietary MIBS brcm emta mgmt mib ...
Страница 54: ...U10C034 Telephony Version v1 4 June 2008 54 3 4 CM Hardware ...
Страница 55: ...55 3 5 Event Log ...
Страница 56: ...U10C034 Telephony Version v1 4 June 2008 56 3 6 CM State ...
Страница 58: ...U10C034 Telephony Version v1 4 June 2008 58 3 8 Product Display status interface information ...
Страница 59: ...59 3 9 DHCP Display CM and MTA DHCP information ...
Страница 60: ...U10C034 Telephony Version v1 4 June 2008 60 3 10 MTA Display some detail MTA parameters ...
Страница 61: ...61 3 11 QoS Display service flow information ...
Страница 62: ...U10C034 Telephony Version v1 4 June 2008 62 3 12 Config Params Display CM and MTA config files information ...
Страница 63: ...63 3 13 Event Log Display CM and MTA event logs ...
Страница 89: ...89 7 Appendix A eMTA LED Behavior This section describes a matrix details the U10C034 LED behavior ...
Страница 90: ...U10C034 Telephony Version v1 4 June 2008 90 U10C034 Telephony MSO User s Manual ...