U10C034 MSO User’s Manual v1.4 June 2008
43
emtaSignalingEndptCtrlDiagTestsStart
(1.3.6.1.4.1.4413.2.2.2.1.6.4.1.1.3.x BITS)
This object is used to start one or more diagnostic tests associated with
a corresponding endpoint. Thus, whenever one or more BITS corresponding
to diagnostic test are set to a value of '1', the MTA will conduct those
tests. Before starting the test, the MTA
clears all the BITS of the following
MIBS:
‧
emtaSignalingEndptCtrlDiagTestValid
‧
emtaSignalingEndptCtrlDiagTestResult
‧
emtaSignalingEndptCtrlDiagTestsStop
Once the designated tests are completed the MTA updates the corresponding
BITS in the MIBS:
‧
emtaSignalingEndptCtrlDiagTestValid
‧
emtaSignalingEndptCtrlDiagTestResult
Whenever
a
test
is
being
run
on
an
endpoint
the
corresponding
'ifOperStatus'
MIB object is set to a value of 'testing(3)' for the duration of the test.
When the test is completed, the MTA sets ifOperStatus to the value
corresponding to the current state of the line. The selected tests will
not run if the corresponding endpoint is offhook. To force execution of
the selected tests regardless of the endpoint status set the corresponding
startForceTestExecution(11) BIT.
‧
startTipToGroundShortDetection(0)
‧
startRingToGroundShortDetection(1)
‧
startTipToRingShortDetection(2)
‧
startRingerEquivalenceNetwork(3)
‧
startSelfTestNoReboot(4)
‧
startOffHookSimulationTest(5)
‧
startTip1ToRing2Short(6), -- Not currently implemented
‧
startTip2ToRing1Short(7), -- Not currently implemented
‧
startHazardousPotentialsTest(8),
‧
startstartForeignElectromotiveForceTest(9),
‧
startReceiverOffhook(10),
‧
startForceTestExecution(11)
emtaSignalingEndptCtrlDiagTestsStop
(1.3.6.1.4.1.4413.2.2.2.1.6.4.1.1.4.x BITS)
This object is used to stop the test corresponding to the bit being set
if the test is not complete yet by the time when the bit is set.
‧
stopTipToGroundShortDetection(0),
‧
stopRingToGroundShortDetection(1),
‧
stopTipToRingShortDetection(2),
‧
stopRingerEquivalenceNetwork(3),
Содержание U10C034
Страница 1: ...U10C034 Telephony MSO User s Manual Version 1 4 Date Aug 2008 ...
Страница 2: ...U10C034 Telephony Version v1 4 June 2008 ii ...
Страница 4: ...U10C034 Telephony Version v1 4 June 2008 iv ...
Страница 17: ...U10C034 MSO User s Manual v1 4 June 2008 17 ...
Страница 19: ...U10C034 MSO User s Manual v1 4 June 2008 19 brcm cm mgmt mib Broadcom eMTA Proprietary MIBS brcm emta mgmt mib ...
Страница 54: ...U10C034 Telephony Version v1 4 June 2008 54 3 4 CM Hardware ...
Страница 55: ...55 3 5 Event Log ...
Страница 56: ...U10C034 Telephony Version v1 4 June 2008 56 3 6 CM State ...
Страница 58: ...U10C034 Telephony Version v1 4 June 2008 58 3 8 Product Display status interface information ...
Страница 59: ...59 3 9 DHCP Display CM and MTA DHCP information ...
Страница 60: ...U10C034 Telephony Version v1 4 June 2008 60 3 10 MTA Display some detail MTA parameters ...
Страница 61: ...61 3 11 QoS Display service flow information ...
Страница 62: ...U10C034 Telephony Version v1 4 June 2008 62 3 12 Config Params Display CM and MTA config files information ...
Страница 63: ...63 3 13 Event Log Display CM and MTA event logs ...
Страница 89: ...89 7 Appendix A eMTA LED Behavior This section describes a matrix details the U10C034 LED behavior ...
Страница 90: ...U10C034 Telephony Version v1 4 June 2008 90 U10C034 Telephony MSO User s Manual ...