507961-01
Page 48 of 58
Issue 2128
Blower Performance
96G2UH045BV12
Temp. Rise
Speed Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting D
Setting C
Setting B
Setting A
High Fire
35-65
+
745
875
990
1005
Normal
685
765
895
910
-
610
695
785
810
Low Fire
20-50
+
685
765
895
910
Normal
620
705
800
820
-
545
625
715
725
Cooling Stage
Cooling CFM @ 0 - 0.8” w.c.
2nd Stage
+
905
1075
1210
1370
Normal
815
980
1120
1255
-
720
885
1020
1135
1st Stage
+
595
760
865
980
Normal
540
660
785
890
-
485
600
695
790
96G2UH070BV12
Temp. Rise
Speed Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting D
Setting C
Setting B
Setting A
High Fire
50-80
+
965
1130
1255
1400
Normal
880
990
1140
1295
-
810
890
1030
1170
Low Fire
25-55
+
940
1070
1195
1345
Normal
830
965
1100
1235
-
755
840
975
1130
Cooling Stage
Cooling CFM @ 0 - 0.8” w.c.
2nd Stage
+
860
1060
1215
1365
Normal
810
960
1130
1265
-
705
840
1005
1140
1st Stage
+
600
740
840
970
Normal
555
665
770
855
-
500
600
680
790