92
801683
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
(5) If area or space permits, lift cabinet top to a
vertical position by hinging it on the rear
hinges.
NOTE: To avoid damage to hinges, be sure to
support cabinet top with a small chain or something
similar. Refer to Figure 23.
(6) Disconnect wire harnesses from coin drop.
(7) Using CK096 Mounting Tool Kit, slide
mounting tool over guide wire and insert
guide wire into hole in mounting tool
(located on notched end of mounting tool).
Refer to
.
NOTE: It is necessary to first slide opposite end of
mounting tool through clearance holes in divider
for easy access to guide wires. Refer to Figure 37.
(8) Loosen nut attaching coin drop to guide
wire. Use mounting tool handle for
increased leverage. Refer to
.
(9) Remove nut.
(10) Repeat for other nut.
(11) Slide coin drop off guide wires and remove
from washer.
b. Installation:
(1) Place coin drop into the control cabinet,
align holes with guide wires, and slide into
position.
(2) Position the coin drop all the way to the
front.
(3) Place one nut, smooth end first, onto a
guide wire and slide to front of coin drop.
Slide mounting tool (from kit CK096) over
guide wire and insert guide wire into hole in
mounting tool (located on notched end of
mounting tool).
NOTE: It is necessary to first slide opposite end of
mounting tool through clearance holes in divider
for easy access to guide wires. Refer to Figure 37.
(4) Tighten nut with mounting tool, using
mounting tool handle for increased
leverage.
(5) Repeat for other nut.
(6) Check guide wire on right side for
interference with coin return. If
interference is found, the rod may need to
be adjusted away from the drop.
(7) Reconnect wire harnesses to coin drop.
(8) Lower cabinet top into position and
reinstall two screws (previously removed)
holding cabinet top to top front edge of
control cabinet front. Refer to
(9) Reinstall control panel in control cabinet
and lock control panel.