801683
17
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
(6) Rotate spring clockwise, 40 to 60 degrees,
until it is free from right tabs. Refer to
.
(7) Use screwdriver to remove spring from
center tab. Refer to
(8) Lift spring, with attached clip, off drop.
(9) Remove clip from spring. Refer to
.
(10) Attach clip to new tension spring, Part No.
209/00598/02.
(11) Place clip, installed on spring, in slot on
(12) Use a small flathead screwdriver to push
spring under center tab. Refer to
.
(13) Lift spring gently to place in position under
left tab.
(14) Push spring to right until it snaps into
.
(15) Close coin drop cover.
Figure 6
Figure 7
MIX3B
MIX3B
Tabs
Center Tab
MIX4B
Clip
MIX4B
Figure 8
Figure 9
MIX8B
Slot
MIX8B
MIX5B
Left Tab
Center
Tab
Small Flat
Screwdriver
MIX5B
Содержание HWFB61QN1102
Страница 2: ......
Страница 14: ...12 801683 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 70: ...68 801683 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...