i. Check for concentricity/roundness of assembly.
Use a dial indicator to check that concentricity
at the inside edge of inner basket lip is a
maximum of .05 inch TIR (Total Indicator
Runout). Refer to
. If concentricity is
not within .05 inch, remove assembly from
washer and adjust location of trunnion. Repeat
until concentricity is within .05 inch.
j. Remove inner basket/trunnion assembly from
washer and evenly torque three nuts to 200 ± 10
inch-pounds.
k. Recheck that concentricity is still within .05
inch.
Inner Basket Installation –
a. Apply No. 27604P Anti-Seize Compound to
the area of the trunnion shaft that will be
contacting the front and rear bearings. Refer to
.
b. Apply a film of grease to area of shaft that will
be contacting the bearing housing seal. Refer to
. Make sure seal lips also are packed
c. Install inner basket assembly by pushing all the
way into outer tub.
d. Install pulley, flat washer, lockwasher and left
.
IMPORTANT: When installing pulley, always use a
new cap screw (included in kit) to prevent screw
from loosening during operation. Use a thread tap
to clean old Loctite out of pulley screw receiving
hole before installing new screw. This ensures that
inner basket and pulley properly seat.
e. Unscrew left hand thread screw half way.
f. Install pulley bolt tightening fixture between
the flat washer and the pulley. Refer to
.
g. Tighten left hand thread screw until washer is
against pulley bolt tightening fixture.
h. Loosen screw about one half turn to free
fixture.
i. Remove pulley bolt tightening fixture.
j. From front of washer, pull inner basket forward
as far as possible. Flat washer should be against
pulley.
k. Push inner basket back into outer tub as far as
possible.
l. Tighten left hand thread screw. Be careful not
to push the trunnion shaft forward while
tightening the screw.
NOTE: Torque new left hand thread screw to 240
minimum to 260 maximum inch pounds (27.5 to
29.7 Nm).
Figure 54
FLW12K
Dial Indicator
Inner
Basket
Outer
Tub
Inner
Basket Lip
Содержание HWFB61QN1102
Страница 2: ......
Страница 14: ...12 801683 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 70: ...68 801683 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 138: ...136 801683 Section 6 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...