T068 [Opto Out Logic]
Determines the logic (Normally Open/NO or Normally Closed/NC) of the opto output.
.
Note:
Setting output to NC may cause output to “glitch” on power-up. The off/reset state of all outputs is open.
Values
Default:
0
Min/Max:
0/1
Display:
1
T058 Option
Opto Out Logic
0
NO (Normally Open)
1
NC (Normally Closed)
T069 [Analog In 1 Sel]
Sets the analog input signal mode (0-20mA, 4-20mA, or 0-10V). This parameter must match DIP Switch AI1 setting on the control board.
.
Values
Default:
2
Min/Max:
0/6
Display:
1
T069 Option
Setting
Input Range
DIP Switch AI1 Setting
0
Current Mode
0-20 mA
20 mA
1
Current Mode
4-20 mA
20 mA
2
Voltage Mode - Unipolar
0-10V
10V
4
Current Mode (Square Root)
0-20 mA
20 mA
5
Current Mode (Square Root)
4-20 mA
20 mA
6
Voltage Mode - Unipolar (Square Root) 0-10V
10V
T070 [Analog In 1 Lo]
,
,
,
,
Stop drive before changing this parameter.
Sets the analog input level that corresponds to
[Minimum Freq].
Analog inversion can be accomplished by setting this value larger than
[Analog In 1 Hi].
Values
Default:
0.0%
Min/Max:
0.0/100.0%
Display:
0.1%
IMPORTANT
If analog inversion is implemented the drive will go to maximum frequency in the event the analog input is lost. It is strongly recommended to activate
T072 [Analog In 1 Loss] to protect from this potential occurrence.
0
P0
3
5 [Maximum Fre
q
]
P0
3
4 [Minimum Fre
q
]
T070 [Analog In 1 Lo]
T071 [Analog In 1 Hi]
0
Speed Reference
T071 [Analog In 1 Hi]
,
,
,
,
Stop drive before changing this parameter.
Sets the analog input level that corresponds to
[Maximum Freq].
Analog inversion can be accomplished by setting this value smaller than
[Analog In 1 Lo].
Values
Default:
100.0%
Min/Max:
0.0/100.0%
Display:
0.1%
Содержание 22C-B012N103
Страница 8: ...6 Rockwell Automation Publication 22C UM001J EN E January 2017 Summary of Changes Notes...
Страница 46: ...44 Rockwell Automation Publication 22C UM001J EN E January 2017 Chapter 1 Installation Wiring Notes...
Страница 56: ...54 Rockwell Automation Publication 22C UM001J EN E January 2017 Chapter 2 Start Up Notes...
Страница 154: ...152 Rockwell Automation Publication 22C UM001J EN E January 2017 Appendix B Accessories and Dimensions Notes...
Страница 176: ...174 Rockwell Automation Publication 22C UM001J EN E January 2017 Appendix E Modbus RTU Protocol Notes...
Страница 192: ...190 Rockwell Automation Publication 22C UM001J EN E January 2017 Appendix G P1 FloorLevel Network FLN Notes...
Страница 195: ......