4 — Ground and power connections
2902 MainStreet Technical Practices
4-9
May 2002 90-2906-01
Notes
(1)
Check that the EPROMs are properly installed on the Control card.
(2)
Turn the power off, wait 30 seconds, then restart the system. If the problem persists, contact your
technical support representative.
19 HDLC
loopback
(HDLC 3)
This test checks the function of the third
HDLC chip on the Control card by making
a loopback through the DX and then
sending a packet through.
Control card HDLC
test failure
20
E1 Framer
loopback
(Framer 1)
This test writes and reads data to the first
E1 framer and verifies the data integrity.
E1 Framer failure
21
E1 Framer
loopback
(Framer 2)
This test writes and reads data to the
second E1 framer and verifies the data
integrity.
E1 Framer failure
22
Thermometer
This test writes and reads data from a
register on the thermometer chip.
Thermometer not
present or circuit
malfunction
23
SEEP
This test writes and reads data from the
serial EPROM on the Control card.
SEEP test failure
24
125
µ
s timer
This test generates a 125
µ
s interrupt and
verifies that it is generated.
Timer check failure
25
Loopback (LIM 1)
This test sends and receives data over
LIM 1 (LIM 1 must be installed).
LIM 1 failure
26
Loopback (LIM 2)
This test sends and receives data over
LIM 2 (LIM 2 must be installed).
LIM 2 failure
27
SMAC interrupt
This test generates a SMAC interrupt and
verifies that it is correctly generated.
EDX or DX failure, or
CPU interrupt failure
Number
Test
Description
Problem
(2 of 2)
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...