11 — Node parameters
2902 MainStreet Technical Practices
11-3
May 2002 90-2906-01
Computer
A PC can be connected to a serial port either directly or indirectly (remotely through
a Hayes-compatible auto-answer modem). The computer must be running one of the
following software packages:
•
terminal emulation software
A PC running VT100-terminal emulation software can manage the node using the
NMTI. An EIA/TIA-232 compatible device, such as a PC, must be connected to
the other serial port for certain node management activities (such as configuration
database backup and restore).
•
Craft Interface Node Manager
A PC running the Craft Interface Node Manager software can manage the node
using the Craft Interface Node Manager.
•
5620 NM
A PC or a Sun workstation running 5620 NM software can manage the node
using the NMTI. The node manager is sometimes referred to as the NOC.
A 5620 NM connected directly to a 2902 MainStreet system can back up, verify
and restore the configuration database; connected indirectly (via modem), it can
back up and verify, but not restore. For more details, see chapter 30 in
Maintenance
.
•
communications software
A PC running communications software can manage the node using the NMTI.
Table 11-1 lists guidelines for selecting serial port device types.
Table 11-1 Guide for selecting device types
Device type
Select
A VT100-compatible terminal connected directly or indirectly
VT100
A computer running terminal emulation software connected directly or indirectly
VT100
A computer running communications software connected directly or directly
VT100
A computer running 5620 NM software or the Craft Interface Node Manager,
connected directly
CPSS
A printer
PRINTER
A computer running 5620 NM software or the Craft Interface Node Manager,
connected through a modem
CPSS_MODEM
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...