1 — Introduction
1-8
2902 MainStreet Technical Practices
90-2906-01 May
2002
Performance specifications
The E1 HDSL LIM and E1 HDSL LIM2 meet the performance specification for
ETSI ETR 152.
1.4
Optical LIM overview
The E1 Optical LIM converts electrical signals to optical signals. The E1 Optical
LIM supports up to 32 DS0s, with one DS0 (timeslot 0) used for synchronization.
The 31 DS0s available for data transmission provide a bidirectional bandwidth of
2.048 Mb/s over a distance of 15 km (9 mi), using a 1300 nm single-mode fiber.
Full-duplex transmission between two E1 Optical LIMs on separate nodes is
achieved by sending data in one direction at a time, making the E1 Optical LIM
immune to unwanted optical reflections. This method allows a simplex single-mode
cable to be used in a full-duplex application.
The E1 Optical LIM emulates an E1 G.703 LIM; however, the monitor and bypass
modes on the E1 Optical LIM are not supported. The E1 Optical LIM operates
transparently with the node software and has the same configuration and
maintenance functions as the E1 G.703 LIM.
Figure 1-6 shows the E1 Optical LIM in a point-to-point application. Figure 1-7
shows a feeder node application.
Figure 1-6 E1 Optical LIM point-to-point application
10450
PBX
Video
Data
PBX
DNIC
X.21
Video
Data
DNIC
X.21
E1
G.703
LIM
(P2)
E1
G.703
LIM
(P2)
E1
Optical
LIM
(P1)
E1
Optical
LIM
(P1)
2902 MainStreet NTU
2902 MainStreet NTU
15 km
(9 mi)
Fiber cable
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...