22 — HCM rate adaption
2902 MainStreet Technical Practices
22-3
May 2002 90-2906-01
The F and S bits each occupy one element (800 b/s of bandwidth each). Any element
that does not contain an F, S or D represents unused bandwidth.
Figure 22-1 HCM frame
In Figure 22-1, the transport bandwidth is 64 kb/s, the interface speed is 9600 b/s and
the transport position is B7. The right side of the display shows all the current circuit
parameters, including the transport bandwidth (beside the Rate adaption heading).
Procedure 22-1 To configure a data circuit for HCM rate adaption
CONFIG — CIRCUIT — <
pp-c
>
↵
— FUNCTION — RATE_ADAPT — METHOD — HCM
where
pp
is 1 or 9, and
c
is 1 or 2, or A or B
22.3
Transport bandwidth
The transport bandwidth sets the number of D elements available to the data device.
Unlike transparent rate adaption, setting the transport bandwidth does not set the
interface speed. The interface speed is set separately (see section 22.6).
Note —
Some combinations of transport bandwidth, transport
position and data position parameters are incompatible. The first D bit
must be in one of the columns defined by the transport position and
the transport bandwidth.
2902 MainStreet 82211-ab-cd Alarms: No Date 2:57R
DATA CCT: M01-1 NAME:
B7 B6 B5 B4 B3 B2 B1 B0 Configured as : SYNC-DCE-FULL DUPLEX
F0 F S D D D D D D Rate Adaption : HCM - 64 kbps
F1 D D D D D D - - Transport Posn : B7
F2 - - - - - - - - Interface Speed : 9600 bps
F3 - - - - - - - - Data Position : F0-B5
F4 - - - - - - - - Signalling : ON
F5 - - - - - - - - Multi-Drop : DISABLED
F6 - - - - - - - - Clock : SLAVE-LOCKED
F7 - - - - - - - -
F8 - - - - - - - -
F9 - - - - - - - -
D - DATA F - FRAMING BIT S - SIGNALLING BIT
CONFIG CIRCUIT 9-A FUNCTION RATE_ADAPT
1-METHOD 2-TRANSP_BW 3-TRANSP_POS 4-SIG_OFF 5-I/F_SPEED
6-DATA_POSN 7- 8-CANCEL 9-QUIT 0-
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...