18 — RS-232 DCM
18-10
2902 MainStreet Technical Practices
90-2906-01 May
2002
Master and slave circuits must be configured with the same starting data position and
transport bandwidth (see chapters 21 and 22). To facilitate this, the 2902 MainStreet
system automatically sets the master circuit configuration to full duplex and
signaling off, and the slave circuit configuration to half duplex and signaling off.
These settings allow you to overlap the position of the data from these circuits.
For circuits in a multidrop data bridge, if the circuit is configured as gender DCE, the
DCD control signal must be forced on. If the circuit is configured as gender DTE, the
RTS control signal must be forced on.
Do not use the copy adjust function when configuring circuits that are to be part of
the same multidrop data bridge.
Procedure 18-8 To configure a master or slave device
where
pp
is 1 or 9, and
c
is 1 or 2
* Default
SLAVE
DISABLE*
MASTER
CONFIG — CIRCUIT — <
pp-c
>
↵
— FUNCTION — I/F_MODE — MULTIDROP
SK000501
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...