
17 — DNIC and 2B1Q modules
17-6
2902 MainStreet Technical Practices
90-2906-01 May
2002
Procedure 17-5 To set the RTS/CTS delay
The RTS/CTS delay can be set for two-port DTUs. RTS/CTS delay cannot be set for the
2606 MainStreet DTU.
The RTS/CTS delay can only be set when a circuit is configured for half-duplex mode
(see section 17.5) or as a multidrop slave (see section 17.10).
CONFIG — CIRCUIT — <
pp-c
>
↵
— FUNCTION — I/F_MODE — RTS/CTS — <
delay time
>
↵
where
pp
is 1 or 9, and
c
is A or B
delay time
is from 0 to 1250 ms in 10-ms increments (10 ms*)
17.7
Control signals
Control signals provide the handshaking required for call setup, call tear-down and
synchronization. Control signals can be configured as:
•
high (ON)
•
low (OFF)
•
end-to-end (END_TO_END)
End-to-end means the state of the local signal follows that of the signal source at the
remote end of the network. This option is only available when using HCM rate
adaption.
Table 17-1 shows default control signal settings. If the device is configured as
synchronous, DTR and DSR are not functional.
Table 17-1 DNIC and 2B1Q module control signal defaults
Note —
Control signals are the only interface parameter that can be
set for a circuit that is configured as a timing source. It is also the only
interface parameter that can be changed when a circuit is connected.
Gender
Inputs
Outputs
DCE RTS
DTR
ALB
RDL
END_TO_END
END_TO_END
END_TO_END
END_TO_END
DCD
DSR
CTS
RI
END_TO_END
FORCED_ON
END_TO_END
FORCED_OFF
DTE DCD
DSR
CTS
RI
END_TO_END
END_TO_END
END_TO_END
END_TO_END
RTS
DTR
ALB
RDL
END_TO_END
FORCED_ON
END_TO_END
FORCED_OFF
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...