42
Optical Fusion Splicer Instruction Manual
Appendix 1 Warning Info. List
Warning
Cause
Solution
Left fiber
placed
incorrectly
(LFPC)
1. Left fiber is cleaved
too short
2. Left fiber loaded in V-
groove is break
3. Left fiber isn’t loaded
in V-groove center.
4. Left motor wire fault.
1. For cause 1&2, re-
cleave left fiber for
correct length.
2. For cause 3, re-load
left fiber.
3. Exclude cause 1,2,3,
run “Detect System
Parameter” or contact
with factory
Right fiber
placed
incorrectly
(RFPC)
1. Right fiber is cleaved
too short
2.Right fiber loaded in
V-groove is break
3.Right fiber isn’t loaded
in V-groove center.
4. Right motor wire fault
Same with LFPC method
Left and right
fiber load
incorrectly
(LRFPC)
Same with above
Same with above method
Left fiber
unqualified
(LFNQ)
1. Dust on left fiber
2. Bad quality for left
fiber, such as damage of
fiber core or cladding,
incomplete fiber etc.
1. For cause 1, wipe the
left fiber with alcohol
dipped cotton.
2. For cause 2, re-cleave
and re-splice left fiber.