F
5
SAT-17T Fusion Splicer Instruction Manual
V-groove, objective lens should be regular cleaned every month,
but in harsh environment conditions, the cleaning should be
done immediately to ensure the correct alignment.
Stabilizing electrodes if follow situation occurs: replace new
electrodes, electrodes squeak, electrode oxidation, carbon
deposition, high/low temperature, high altitude etc. Doing this
will improve splicing accuracy.
Please follow the instructions for electrodes replacement.
Use only specified electrodes.
Set the new electrodes in the correct position.
Replace the electrodes must in a pair.
Ignore or misunderstanding to follow the above instructions may
cause unusual arc discharge. It can result equipment damage or
degradation in splicing performance.
Do not use any chemical other than pure alcohol (99% or
greater) to clean the objective lens, V-groove, LCD monitor and
other parts of the splicer. Otherwise blurring, discoloration,
damage or deterioration may result.
The splicer requires no lubrication. Oil or grease may degrade
the splicing performance and damage the splicer
The equipment must be repaired or adjusted by an authorized
technician or engineer. Incorrect repair may cause fire or electric
shock. If any problems occurred, please contact your nearest
service or your sales representative directly.