27
Optical Fusion Splicer Instruction Manual
aligning, the screen shows left and right fiber angle. If the
detected end face cleave angle exceed limitation value, an error
message also shows, user need to re-cleave fiber again.
Note:
Set the “End-face Angle Limit” “Fiber Align Limit” in
“Splice Mode” menu.
If the below prompt info. while aligning, the system will auto-
reset motors, user can also press to reset motor, and re-cleave
or re-load fiber.
Image
(X/Y axis)
Prompt
Info.
Probable
Reason
Measureme
nt
Incorrectly
placed
right fiber
Right fiber is not
load into V-
groove, or cleave
too short
Reload fiber,
re-cleave
fiber
Incorrectly
placed left
fiber
Left fiber is not
load into V-
groove, or cleave
too short
Reload fiber,
re-cleave
fiber
Abnormal
alignment
Left/right fiber is
not loaded into V-
groove
Reload fiber,
re-cleave
fiber
Re-load
fiber
Left and right
fiber is cleaved
too short.
Reload fiber,
re-cleave
fiber