44
Optical Fusion Splicer Instruction Manual
limited value
2. Mismatching fiber
splice mode is chosen
groove, re-operate “ARC
Calibration” and re-splice
2. For cause 2, replace to
proper splice mode
Low power
Current battery
Electricity is low than
2%
Connect power adaptor
to charge
Replace
electrodes
ARC times is exceed the
limited value
Operate “Replace
Electrodes”, then do
“Detect System
Parameter”
Records
exceed
limitation
Splice records quantity
is exceed limited value
Download the original
splice records by USB,
then contact with
Authorized company to
operate Reset Counter
Abnormal
aligning
1. Dust on end-face or
bad quality end-face.
2. Fiber is pressed
tightly by wind
protector cover
Re-cleave and clean fiber,
then try to re-align, if the
fault still exist, run
“Detect System
Parameters”
Abnormal
overtime
Run in too long time
during fiber aligning
process
Re-splice, if the fault
continuous occur, re-
start fusion splicer
Abnormal
view field
1. Incorrectly install the
electrodes
2. Fusion splicer inner
Execute “Detect System
Parameter”, if still
prompt fault, re-install