Aisino RCK-600 User Guide
Error card
exit:
LEFT SIDE
\
RIGHT
SIDE
Magnetic/IC
Pos:
Front\
Back
Eject
Face:
Auto\Front Up\
Back
Up
C
ard Feed Mode:
card cassette\
Right(Manual)
\Right(Auto)
Card
thickness:
thick
\thin
Card
Type
35mm/s and
202
℃
are the default settings for Card 1
-
3 (Card Type is cut off
above)
Excessive heat can bend cards. Even optimized retransfer conditions
(speed/temperature) sometimes causes cards to bend. Change this setting
to minimize the degree of bend.
User can set up 0-
5 (S) for correcting. The
correcting time of front: the default value is
“
1”;The correcting time of
reverse side :the default value is
“0
”; 1 means correct the bend card for 1
second;0 means do not correct the bend card.
Valid Settings
Details
PVC (Default)
Apply optimized retransfer conditions for standard PVC cards.
PET
Apply optimized retransfer conditions for standard PET cards.
PET
-G
Apply
optimized retransfer conditions for standard PET
-G cards.
Card1
(
aa
,
bb
)
aa=
re-retransfer
speed, when the value of aa is increased, the re
-
retransfer speed get faster; when the value of aa is reduce, the re
-
retransfer speed get slower.
bb= default re-
retransfer temperature, when the value of bb is increase,
the re-
retransfer temperature is increase; when the value of bb is
reduce, the re
-retransfer get lower.
Card2
(
aa
,
bb
)
Card3
(
aa
,
bb
)
65
Содержание RCK-600
Страница 1: ......
Страница 14: ...Aisino RCK 600 User Guide ...
Страница 30: ...Aisino RCK 600 User Guide 4 Waiting for the installation 5 Finish the installation click the Finish 16 ...
Страница 35: ...Aisino RCK 600 User Guide 9 Waiting for the installation 10 Finish the installation click the Finish 21 ...
Страница 51: ...Aisino RCK 600 User Guide Open the front cover Hold the handle and open the front cover 37 ...
Страница 61: ...Aisino RCK 600 User Guide 47 ...