3
3
- 20
Control of 3-WAY FLOW LOGIC
2. Wireless Remote Controller
Fig. 3-23
Fig. 3-24
Fig. 3-25
●
For flush mounting into a wall, install the separate
receiver unit in a metal switch box (field supply)
that has been recessed into the wall in advance.
1. Insert a flathead screwdriver or similar tool into the
notch, and remove the face plate.
2. Fix the receiver unit with 2 M4 screws provided.
Do not overly tighten, and use the provided spac-
ers. If the receiver unit does not fit in the wall, cut
spacers to adjust the clearance.
3. Connect the receiver unit wiring (2-core cable)
with the cables extended from the indoor unit.
(Refer to the section on receiver unit wiring.)
Be sure to determine the correct terminal numbers
on the indoor unit when wiring the receiver unit.
The remote controller will be damaged if high volt-
age (such as 200 VAC) is applied.
4.
Reinstall the face plate.
●
When using exposed mounting for the receiver unit,
install onto a wall where the receiver unit can be
attached.
1. Insert a flathead screwdriver or similar tool into the
groove on the bottom of the receiver unit. Pry
open with the screwdriver and remove the lower
case. (Fig. 3-23).
2. In order to later pass the receiver wiring out
through the upper case (thin part at the top cen-
ter), use nippers or a similar tool to cut a notch in
the same size as the remote controller cord
(optional). (Fig. 3-24)
3. Disconnect the wires that were connected to the
connector at the time of shipment.
4. Fasten the remote controller cord (optional) at the
position shown in Fig. 3-25, using the provided
clamp. Then connect the cord to the receiver con-
nector.
5. Shape the remote controller cord as shown in Fig.
3-25 so that it fits at the top inside the receiver
unit, above the PCB. Then attach the lower case.
At this time, bend the head of the clamp so that it
faces sideways.
6. Remove the nameplate and use 2 wood screws to
attach the receiver unit.
7. Use the provided cord clips to fasten the remote
controller cord to the wall.
8. Reattach the nameplate.
●
If the separate receiver unit is installed on the ceil-
ing, use the provided ceiling mounting bracket for
installation.
Face plate
Notch where remote
controller cord passes
through top case
Remote controller
cord (optional)
Connector
Clamp
2 3 mm
1
3
2
4
6
5
Remote controller cord
(optional)
Receiver unit
Clamp
Wood
screws (2)
04-218 Airwell-3_1-38.qxp 01/06/2007 13:14 Page 20
Содержание EFL 100-3R410
Страница 300: ...6 6 15 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NWFL 24 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 15...
Страница 306: ...6 6 21 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 24 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 21...
Страница 308: ...6 6 23 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 36 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 23...
Страница 310: ...6 6 25 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 48 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 25...
Страница 312: ...6 6 27 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 76 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 27...
Страница 314: ...6 6 29 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 96 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 29...
Страница 315: ...6 6 30 Electrical Data 2 Indoor Unit 8 Electric Wiring Diagram ST NDHP 96 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 30...