2
2
- 6
Design of 3-WAY FLOW LOGIC
1. Model Selecting and Capacity Calculator
■
■
Tubing size
Main Tubing Size (LA)
Unit: mm
ø19.05
ø38.10
ø19.05
ø28.58
ø31.75
ø31.75
ø15.88
ø28.58
ø12.70
ø25.4
ø9.52
ø22.22
ø15.88
ø15.88
ø19.05
ø15.88
ø19.05
ø19.05
ø22.22
ø9.52
ø9.52
ø9.52
ø12.70
(mm)
(mm)
–
70.0
(25 hp)
58.8
(21 hp)
7.1
(2.5 hp)
7.1
(2.5 hp)
98.0
(35 hp)
–
103.6
(37 hp)
25.0
(6 hp)
16.0
(6 hp)
16.0
(6 hp)
25.0
(9 hp)
75.6
(27 hp)
ø19.05
ø28.58
ø38.10
103.6
(37 hp)
98.0
(35 hp)
ø19.05
ø25.4
ø31.75
75.6
(27 hp)
70.0
(25 hp)
30.0
(11 hp)
ø12.70
ø25.4
ø19.05
30.0
(11 hp)
36.4
(113 hp)
36.4
(13 hp)
Below kW
Over kW
42.0
(15 hp)
ø12.70
ø28.58
ø22.22
ø22.22
ø25.40
42.0
(15 hp)
47.6
(17 hp)
ø15.88
ø28.58
47.6
(17 hp)
58.8
(21 hp)
Total capacity
after distribution
Tubing size
Suction tubing
(mm)
Liquid tubing
Discharge tubing
hp = horsepower
Unit: mm
(mm)
(mm)
Below kW
Over kW
Total capacity
after distribution
Tubing size
Suction tubing
(mm)
Liquid tubing
Discharge tubing
34
32
85.0
30
78.5
28
73.0
26
ø22.22
ø22.22
ø25.40
ø28.58
10
28.0
33.5
12
ø25.4
ø12.70
14
40.0
45.0
16
ø28.58
ø28.58
ø15.88
18
50.4
8
10
10
10
56.0
20
ø19.05
ø31.75
22
61.5
10
14
10
10
10
16
12
16
14
14
10
10
16
12
10
16
14
10
16
16
10
16
16
12
16
16
14
16
16
16
16
16
16
16
68.0
24
22.4
8
ø19.05
ø15.88
ø19.05
ø9.52
90.0
101.0
106.5
113.0
118.0
40
42
ø38.10
ø31.75
ø28.58
44
46
ø19.05
48
135.0
130.0
123.5
38
36
96.0
14
16
12
10
12
8
10
kW
Total system
horsepower
Total system
horsepower
Combined
outdoor units
Combined
outdoor units
Suction tubing (mm)
Suction tubing (mm)
Discharge tubing (mm)
Liquid tubing (mm)
Discharge tubing (mm)
Liquid tubing (mm)
kW
■
Size of tubing (LO) between outdoor units
Select the size of tubing between outdoor units based on the main tubing size (LA) as given in the table above.
Main Tubing Size After Distribution (LB, LC...)
*1:If future extension is planned, select the tubing diameter based on the total horsepower after extension.
However extension is not possible if the resulting tubing size is two ranks higher.
*2:The balance tube (outdoor unit tube) diameter is
φ
9.52.
*3:Type 1 tubing should be used for the refrigerant tubes.
*4:If the longest main tube length (LM) exceeds 50 m, increase the main tube size at the portion before 50 m by 1 rank for the
suction tubes and discharge tubes.
(For the portion that exceeds 50 m, set based on the main tube sizes (LA) listed in the table above.)
*1:
The outdoor unit connection tubing (LO) is determined by the total capacity of the outdoor units connected to the tube
ends. The tubing size is selected based on the table of main tube sizes after the branch.
*2:
If the total capacity of the indoor units connected to the tube ends is different from the total capacity of the outdoor units,
then the main tube size is selected based on the total capacity of the outdoor units.
(For LA, LB, and LF in particular)
04-218 Airwell-2.qxp 01/06/2007 13:15 Page 6
Содержание EFL 100-3R410
Страница 300: ...6 6 15 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NWFL 24 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 15...
Страница 306: ...6 6 21 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 24 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 21...
Страница 308: ...6 6 23 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 36 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 23...
Страница 310: ...6 6 25 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 48 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 25...
Страница 312: ...6 6 27 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 76 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 27...
Страница 314: ...6 6 29 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 96 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 29...
Страница 315: ...6 6 30 Electrical Data 2 Indoor Unit 8 Electric Wiring Diagram ST NDHP 96 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 30...