Control of 3-WAY FLOW LOGIC
2. Wireless Remote Controller
CN1
(optional)
(optional)
1 2
1 2
Indoor
unit
(sub)
(main)
Receiver unit
Remote controller
terminal board
Ground
Wireless remote
controller kit
Wired remote
controller
Remote control wiring (field supply)
When 1 indoor unit is operated with 2 remote controllers:
(The indoor unit runs according to which of the remote controllers is assigned as the main or sub unit.)
*
*
* Use field wiring cables with a
cross-sectional area of at least
0.5mm
2
to 2mm
2
.
* The maximum total length of
crossover cables must be no
longer than 400m.
CN1
(optional)
1 2
1 2
(optional)
Indoor
unit No.1
Indoor
unit No.2
Indoor
unit No.3
Indoor
unit No.4
Receiver
unit
(Main)
(Sub)
Remote controller
terminal board
When several groups of indoor units are operated with 2 remote controllers:
(The remote controller (main or sub unit) can operate with any indoor unit.)
Wireless remote
controller kit
Wired remote
controller
Remote control
wiring among the
control groups
(field supply)
* Use field wiring cables with a
cross-sectional area of at least
0.5mm
2
to 2mm
2
.
* The maximum total length of
crossover cables must be no
longer than 200m.
*
*
Ground
Ground
Ground
Ground
Fig. 3-6
Fig. 3-5
(1) To assign the wired remote controller as the sub unit,
locate the address connector at the rear of the wired
remote controller PCB and disconnect it. Reconnect it to
the sub unit position.
(2) To assign the wireless remote controller as the sub unit,
locate the dip switch [S003] on the wireless receiver unit
PCB. Set the No. 3 switch to the ON position.
2-5. How to use the Test Run Setting
1. Set DIP switch [S003] No. 1 on the wireless receiver
unit PCB from OFF to ON.
2. All indicator lamps in the display section blink during
test run operation.
3. No temperature control is available during the test run.
4. After the test run, be sure to reset DIP switch No. 1
back to the OFF position and check that no indicator
lamps are blinking. Then remount and attach the PCB
cover as before.
To avoid placing excessive operating load on the equip-
ment, use this function only when conducting the test run.
NOTE
Receiver PCB
Receiver unit
cover
ON
1
2
3
4
Adjustable
corner cap
S003
Bit 1: OFF ON
04-218 Airwell-3_1-38.qxp 01/06/2007 13:14 Page 10
Содержание EFL 100-3R410
Страница 300: ...6 6 15 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NWFL 24 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 15...
Страница 306: ...6 6 21 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 24 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 21...
Страница 308: ...6 6 23 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 36 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 23...
Страница 310: ...6 6 25 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 48 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 25...
Страница 312: ...6 6 27 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 76 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 27...
Страница 314: ...6 6 29 Electrical Data 2 Indoor Unit Schematic Wiring Diagram ST NDHP 96 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 29...
Страница 315: ...6 6 30 Electrical Data 2 Indoor Unit 8 Electric Wiring Diagram ST NDHP 96 04 218 Airwell 6 qxp 01 06 2007 13 23 Page 30...