66
the unit is higher or lower than
normal
7
★
Ο
★
×
Communicatio
n failure
between the
indoor unit and
outdoor unit
a.
the communication cable
connect loose;
b.
the communication cable is
failure;
c.
the connection between the filter
board and the outdoor control
board is incorrect or loose;
d.
the connection between the filter
board and the terminal is incorrect
or loose;
e.
the indoor control board is failure;
f.
the PFC board is failure;
g.
the power board is failure;
h.
the outdoor control board is
failure.
8
★
Ο
★
★
Current
overload
protection
a.
the fan motor run abnormally;
b.
the condensor and evaporator is
dirty;
c.
the air inlet and outlet is
abnormally
9
×
×
Ο
×
Maximum
current
protection
a.
the outdoor control board is short
circuit;
b.
the drive board is short circuit;
c.
the other components is short
circuit
10
×
×
Ο
★
Communicatio
n trouble
between
outdoor unit
and driver
a.
the connection wires connect
loose
b.
the outdoor board or drive
board is failure;
11
×
★
Ο
×
Outdoor
EEPROM in
trouble
a.
the EEPROM chip is loose;
b.
the EEPROM chip inserted with
opposite direction;
c.
the EEPROM chip is failure
Содержание ABSCI4H4S09
Страница 1: ...1 Service Manual...
Страница 20: ...20 Outdoor Units Unit All Models View Remote controller Model All Models View...
Страница 27: ...27 Indoor 1852066 1854605...
Страница 28: ...28 1854698...
Страница 29: ...29 Outdoor 1854707...
Страница 47: ...47 ASRCI4H4S18 ASRCI4H4S24 ABSCI4H4S12 ABSCI4H4S18...
Страница 50: ...50 6 2 Fan Motor Drawings attached...
Страница 74: ...74 Air Con International Inc 1802 SW 2nd St Pompano Beach FL 33069 Tel 954 771 1415 Fax 954 771 1418...