69
c.
The indoor control board is
failure.
34
o
x
★
x
The failure for
temperature
sensor of
indoor coil
temperature
a.
The indoor coil temperature
sensor loose;
b.
The indoor coil temperature
sensor is failure;
c.
The indoor control board is
failure.
36
Ο
★
×
★
Communicatio
n failure
between the
indoor unit and
outdoor unit
a.
the communication cable
connect loose;
b.
the communication cable is
failure;
c.
the connection between the filter
board and the outdoor control
board is incorrect or loose;
d.
the connection between the filter
board and the terminal is incorrect
or loose;
e.
the indoor control board is failure;
f.
the PFC board is failure;
g.
the power board is failure;
h.
the outdoor control board is
failure.
38
o
★
★
★
Indoor
EEPROM
failure
a.
The EEPROM chip loose;
b.
The indoor control board is
failure
39
o
x
★
★
Indoor fan
motor run
abnormally
a.
There are something block the
indoor fan motor;
b. The fan motor cord connect
loose;
c. The fan motor is failure;
d. The indoor control board is
failure
41
★
★
o
★
The failure for
Indoor
grounding
The indoor control board is failure
Содержание ABSCI4H4S09
Страница 1: ...1 Service Manual...
Страница 20: ...20 Outdoor Units Unit All Models View Remote controller Model All Models View...
Страница 27: ...27 Indoor 1852066 1854605...
Страница 28: ...28 1854698...
Страница 29: ...29 Outdoor 1854707...
Страница 47: ...47 ASRCI4H4S18 ASRCI4H4S24 ABSCI4H4S12 ABSCI4H4S18...
Страница 50: ...50 6 2 Fan Motor Drawings attached...
Страница 74: ...74 Air Con International Inc 1802 SW 2nd St Pompano Beach FL 33069 Tel 954 771 1415 Fax 954 771 1418...