65
Refer to the remote controller which the sleep key can set into 4 different combination ways (Hisense's new
design remote controller), when using to check the error codes only takes effect for pressing the sleep key 10
times in ten seconds instead of 4 times.
NOTE: If the troubleshooting inquiry display by 7-segment tube, then the error code will be displayed,
otherwise only the LED of the display board can show.
Erro
r
cod
e
Runnin
g
Time
r
Slee
p
Powe
r
Remark
:★
Light o Flash x OFF
1
2
3
4
Content
Remar
k
The root cause is may be one of
the following
0
Normal
1
x
o
x
x
The failure for
temperature
sensor of
outdoor coil
a.
The outdoor temperature
sensor loose;
b.
The outdoor temperature
sensor is failure;
c.
The indoor control board is
failure
2
×
Ο
★
×
Compressor
exhaust
temperature
sensor in
trouble
a.
the compressor exhaust
temperature sensor connect
loose;
b.
the compressor exhaust
temperature sensor is failure;
c.
the outdoor control board is
failure
5
★
Ο
×
×
IPM module
protection
a.
The IPM board is failure;
b.
The outdoor fan is broken;
c.
The outdoor fan motor is failure;
d.
The outdoor fan has been
blocked ;
e.
The condenser is dirty;
f.
The outdoor unit has been
installed without standard.
6
★
Ο
×
★
AC voltage
higher or lower
protection
a.
the supply voltage is higher
or lower than normal;
b.
the inner supply voltage of
Содержание ABSCI4H4S09
Страница 1: ...1 Service Manual...
Страница 20: ...20 Outdoor Units Unit All Models View Remote controller Model All Models View...
Страница 27: ...27 Indoor 1852066 1854605...
Страница 28: ...28 1854698...
Страница 29: ...29 Outdoor 1854707...
Страница 47: ...47 ASRCI4H4S18 ASRCI4H4S24 ABSCI4H4S12 ABSCI4H4S18...
Страница 50: ...50 6 2 Fan Motor Drawings attached...
Страница 74: ...74 Air Con International Inc 1802 SW 2nd St Pompano Beach FL 33069 Tel 954 771 1415 Fax 954 771 1418...