36
2-1 Display panel
I. Control functions of the remote controller (See operating and installation manual)
II. Display of the indoor unit
Information on the screen:
Displaying Scheme:
7-segment tube
:
Display set temperature or indoor temperature , and display fault code in trouble
indicating. An error code is displayed according to the signal from the indoor CPU. The error code will
flash for 5 seconds while displayed.
Running LED
:
It is on during operation. It is flashing when the unit defrost.
TIMER LED
:
When the timer mode works, the LED will be lighted.
Sleep LED
:
When the sleep mode works, the LED will be lighted, and after 10s, the LED will be off.
Compressor LED
:
It lights up when compressor is running.
Remote control receiver
:
This section receives signals from the remote control.
3. Control function
3-1 Emergency switch
If the appliance under the Stand-by state, all the Operation Mode, Air volume, Temperature
Setting , Forced Cooling function will be restored as the last time setting when you press on the
“ON/OFF” button, but lost the Air flow direction setting.
If the appliance was connected to the power at first time, it would operate in the auto mode, It
will keep in stand-by state if you press the “ON/OFF” button during the normal operation.
When the appliance under the Stand-by state, press and hold the emergency switch for 5
seconds, the buzzer rings for 1 times, and it will operate in cooling mode, and the indoor fan speed
is set to high-speed, it running has nothing to do with the room temperature.
When press the emergency switch or receive the signal of the remote control, it will exit this
mode, and it will operate with the corresponding order.
3-2 Operator-machine communication
If the unit has I feel function, when the I feel function is set by the remote control, the room
temperature will depend on the remote control and it will be detected by the sensor of the remote
control. Normally the remote control will automatically transmits a signal at an interval of 10
minutes
(
only for H1 remote control, it is 9 minutes
)
, but if the room temperature changed exceed
1
℃
in a short period of time, the remote control will transmits a signal within 2 minutes. If the indoor
Содержание ABSCI4H4S09
Страница 1: ...1 Service Manual...
Страница 20: ...20 Outdoor Units Unit All Models View Remote controller Model All Models View...
Страница 27: ...27 Indoor 1852066 1854605...
Страница 28: ...28 1854698...
Страница 29: ...29 Outdoor 1854707...
Страница 47: ...47 ASRCI4H4S18 ASRCI4H4S24 ABSCI4H4S12 ABSCI4H4S18...
Страница 50: ...50 6 2 Fan Motor Drawings attached...
Страница 74: ...74 Air Con International Inc 1802 SW 2nd St Pompano Beach FL 33069 Tel 954 771 1415 Fax 954 771 1418...