37
unit has not received a remote signal within 30 minutes, the room temperature will depend on the
room temperature sensor of indoor unit.
3-3 Timer function
Real time of Timer setting
(1) The max Timer ranges is 24 hours.
(2) Timer ON/OFF
(3) Timer ON/OFF can be set available in turn.
(4) The Timer accurate more than 97%
(5) The Timer can be adjusted by 1 min increase.
(6) The appliance can be set the ON-Timer and OFF-Timer in the same time, but no any timer
setting indicated.
3-4 Sleep
(1)The Sleep mode can only be set during Cool, Heat and Dry mode.
(
2
)
When the appliance run in the Sleep mode, it will stop after 8 hours operation, then it will
cancel the Sleep setting. When the appliance operate under the OFF-Timer setting condition, if the
OFF-Timer setting less than 8 hours, it will keep the Sleep mode till the OFF-Timer setting; if the
OFF-Timer setting more than 8 hours, it will cancel the OFF-Timer setting after the Sleep mode OFF.
(
3
)
When the Sleep mode is select with Cooling mode, if the room temperature not less than
26
℃
, the setting temperature will not be adjusted, otherwise, the setting temperature will be raised
by 1
℃
per hour, but the max setting temperature raise is 1
℃
.
(
4
)
When the Sleep mode is select with Heat mode, the setting temperature will be decreased
by 1
℃
per hour during the successive 3 hour, but the max setting temperature decrease is 3
℃
.
(
5
)
When the appliance operate with Sleep mode, the indoor fan run in the LOW setting, and
the air flow direction same as the last setting and the temperature and air flow direction can be
adjusted by user. The Running indicator will be flashed 10 times per 1 Hz frequency, then all the
indicators turn OFF except the Sleep light after 5 min elapse. Those indicators will be recovery when
the temperature or Time setting is adjusted, after the setting, the indicators will be lit in 10 sec, then
turn OFF.
3-5 Automatic run (SMART) mode
Содержание ABSCI4H4S09
Страница 1: ...1 Service Manual...
Страница 20: ...20 Outdoor Units Unit All Models View Remote controller Model All Models View...
Страница 27: ...27 Indoor 1852066 1854605...
Страница 28: ...28 1854698...
Страница 29: ...29 Outdoor 1854707...
Страница 47: ...47 ASRCI4H4S18 ASRCI4H4S24 ABSCI4H4S12 ABSCI4H4S18...
Страница 50: ...50 6 2 Fan Motor Drawings attached...
Страница 74: ...74 Air Con International Inc 1802 SW 2nd St Pompano Beach FL 33069 Tel 954 771 1415 Fax 954 771 1418...