40
and it is not available when it is subject to the sensor on the remote control.
3-7-2 Indoor fan motor operation
Anti-cold air system:
When the appliance run in Heat mode condition, the indoor fan motor operation is shown as
following to prevent the cooling air come out during the appliance operation.
When the appliance turn in the anti-cold air system in the Extra-LOW (Tapped motor set in LOW,
sic passim) during the compressor operation, the louver swing to the Cool air protection position, the
louver recovers to the original position after the air volume change to LOW. When the room
temperature reach to the setting temperature, the compressor will be turn off, and the air flow
change to LOW, the louver swing to the Cool air protective position to prevent the air drop into human
body directly; when the indoor pipe coil temperature drop continuously, it will turn in the Cooling air
protective system in the Extra-LOW or stop the fan motor.
The indoor fan motor is only controlled by the signal of indoor pipe coil temperature, no matter
the compressor turn ON/OFF, even the appliance turn in Heat mode at first time.
The indoor fan motor will operate according to the different setting(High, Medium, Low and
Automatic) by the remote control, but the anti-cold air system is prior.
When the appliance run in the Heat mode with the Automatic setting at first time, the fan speed
will be in the LOW setting, and the operation diagram is shown as following
Содержание ABSCI4H4S09
Страница 1: ...1 Service Manual...
Страница 20: ...20 Outdoor Units Unit All Models View Remote controller Model All Models View...
Страница 27: ...27 Indoor 1852066 1854605...
Страница 28: ...28 1854698...
Страница 29: ...29 Outdoor 1854707...
Страница 47: ...47 ASRCI4H4S18 ASRCI4H4S24 ABSCI4H4S12 ABSCI4H4S18...
Страница 50: ...50 6 2 Fan Motor Drawings attached...
Страница 74: ...74 Air Con International Inc 1802 SW 2nd St Pompano Beach FL 33069 Tel 954 771 1415 Fax 954 771 1418...