58
42
28.264
0.96965549
113
2.678
3.587254695
43
27.162
1.00111890
114
2.609
3.613561484
44
26.109
1.03315203
115
2.542
3.639477628
45
25.103
1.06573050
116
2.477
3.664977902
46
24.142
1.09883007
117
2.414
3.6900369
47
23.223
1.13246511
118
2.353
3.714629083
48
22.345
1.16658089
119
2.294
3.738728832
49
21.505
1.20120120
120
2.237
3.762310501
50
20.701
1.23631868
Note: the AD value in the table is calculated on the basis of the pull-down resistor is 6.8K.
6-4. Compressor
Drawings attached:
DC
INVERTER
CONTROLLER
&
R U
( )
S V
( )
T W
(
)
OVERLOAD PROTECTION
POWER
Test in resistance.
TOOL: Multimeter.
Test the resistance of the winding. The compressor is fault if the resistance of winding 0(short
circuit)or∞
(
open circuit
)
Содержание ABSCI4H4S09