3-9 Dehumidifying mode
The dehumidifying mode is illustrated as follows:
Dehumidifying area I: Operation at the frequency in the range (30–60Hz) according to Dt (T
indoor
ambient
-T
set
).
Dt(
℃
)
f(Hz)
0
30
0.5
30
1
40
1.5
50
≥2
60
Dehumidifying area II: The compressor stops for 5 minutes and operators for 5 minutes at the lowest
frequency.
Dehumidifying area III: The compressor stops.