background image

Service Manual 

Содержание ABSCI4H4S09

Страница 1: ...1 Service Manual...

Страница 2: ...owing models Outdoor Units Indoor Units ABSCI4H4S09 ABSEM4H4S09 ABSCI4H4S12 ABSEM4H4S12 ABSCI4H4S18 ABSEM4H4S18 ABSCI4H4S24 ABSEM4H4S24 ASRCI4H4S09 ASREM4H4S09 ASRCI4H4S12 ASREM4H4S12 ASRCI4H4S18 ASRE...

Страница 3: ...iring Diagram 26 4 3 Refrigerant Flow System 30 4 4 Air Purging and Leakage Test 31 4 5 Test Running 32 5 Function Operation 34 5 1 Operation Range cooling and heating 34 5 2 Remote Controller Operati...

Страница 4: ...important part of your job to install or service the system so it operates safely and efficiently For safe installation and trouble free operation you must Carefully read this instruction booklet befo...

Страница 5: ...completed or reconnected and checked Highly dangerous electrical voltages are used in this system Carefully refer to the wiring diagram and these instructions when wiring Improper connections and ina...

Страница 6: ...the nut with a torque wrench for a leak free connection Check carefully for leaks before starting the test run When Servicing Turn the power OFF at the main power box mains before opening the unit to...

Страница 7: ...for Heating Btu W 11 63 11 71 10 00 10 75 Moisture Removal L H r 0 9 1 2 2 0 2 4 Air Circulation m3 h 550 620 1000 1150 Refrigerant R410A R410A R410A R410A Refrigerant charge volume g 830 1000 1400 1...

Страница 8: ...27 2 Tube pitch a x row pitch b mm 21x13 6 21x13 6 21x13 6 21x13 6 Fin spacing mm 1 4 1 4 1 4 1 4 Condenser Condenser material Copper tube and Aluminum Fin Number of rows 1 1 5 2 2 Tube outside dia an...

Страница 9: ...11 16x20 7 8x13 3 8 32 11 16x20 7 8x13 3 8 37x25 3 16x15 3 16 39 3 16x28 3 4x17 1 2 Gross Weight Kg Indoor Unit 10 11 0 14 5 17 0 Outdoor Unit 27 30 42 54 0 Loading Capacity NO pipe 40 HC 345 335 195...

Страница 10: ...Yes Yes Yes Compressor Intelligent Pre heating Yes Yes Yes Yes Smart Function Yes Yes Yes Yes Super Function Yes Yes Yes Yes Auto Restart Yes Yes Yes Yes Auto Defrost Yes Yes Yes Yes Auto Cleaning Yes...

Страница 11: ...g Btu W 13 01 11 50 11 90 11 78 E STAR__V5 0 ASHP SEER 15 EER 12 5 HSPF 8 5 CAC SEER 15 EER 12 5 Yes Yes Yes No Most Efficient 2016 ASHP SEER 20 EER 12 5 HSPF 10 CAC SEER 20 EER 12 5 Yes Yes Yes No CE...

Страница 12: ...input W 30 30 60 61 Outdoor motor speed H M L 880 650 450 800 650 450 840 650 500 1200 550 500 Evaporator Evaporator material Copper tube and Aluminum Fin Number of rows 2 2 2 2 Tube outside dia and t...

Страница 13: ...Indoor Unit 8 5 9 0 14 5 14 5 Outdoor Unit 27 0 33 0 45 56 Packing Dimensions WxHxD mm With pipe Indoor Unit mm 900 335 260 900 335 260 1210 390 315 1210 390 315 Indoor Unit in 35 7 16x13 3 16x10 7 1...

Страница 14: ...0 61 86 16 30 61 86 16 30 61 86 16 30 61 86 8 C 46 F Heating to avoid freezing water pipe in Kitchen Yes Yes Yes Yes C F convertible Yes Yes Yes Yes 2 Ways Draining Connection Left or Right Yes Yes Ye...

Страница 15: ...ng Capacity Btu h 31000 Rated Input Cooling W 2900 Rated Input Heating W 2700 SEER Cooling 18 8 HSPF Heating 12 3 EER for Cooling Btu W 10 COP for Heating Btu W 8 5 Moisture Removal L H r 3 Air Circul...

Страница 16: ...0 500 Evaporator Evaporator material Number of rows 2 Tube outside dia and type mm 7 innergroove tube Evaporator length x height x width mm 985x420x27 6 Tube pitch a x row pitch b mm 19x13 6 Fin spaci...

Страница 17: ...oor Unit in 54 1 2x17 1 8x12 13 16 Outdoor Unit mm 1050 910 500 Outdoor Unit in 41 11 32x35 13 16x19 11 16 Gross Weight Kg Indoor Unit 23 0 Outdoor Unit 63 Loading Capacity NO pipe 40 HC 105 Test Stan...

Страница 18: ...n Yes C F convertible Yes 2 Ways Draining Connection Left or Right Yes Compressor Intelligent Pre heating Yes Smart Function Yes Super Function Yes Auto Restart Yes Auto Defrost Yes Auto Cleaning Yes...

Страница 19: ...19 3 Product Picture and Drawing 3 1 Product Pictures Indoor units Front Panel ASREM4H4S09 ASREM4H4S24 View Front Panel ABSEM4H4S09 ABSEM4H4S24 View Front Panel ASPEM4H4S30 View...

Страница 20: ...20 Outdoor Units Unit All Models View Remote controller Model All Models View...

Страница 21: ...ct dimensions Indoor units Model WXHXD mm ASREM4H4S09 745 270 214 ASREM4H4S12 815 270 214 ASREM4H4S18 915 315 236 ASREM4H4S24 1085 315 236 ABSEM4H4S09 870 270 214 ABSEM4H4S12 870 270 214 ABSEM4H4S18 1...

Страница 22: ...m L2 mm L3 mm L4 mm L5 mm L6 mm L7 mm ASRCI4H4S09 443 264 776 715 240 486 290 ASRCI4H4S12 443 264 776 715 240 486 290 ASRCI4H4S18 510 310 873 810 280 585 338 ASRCI4H4S24 542 341 935 860 310 667 368 AB...

Страница 23: ...1 Installation Place and Condition Indoor unit Avoid direct sunlight nearby heat sources that may affect performance of the unit areas where leakage of flammable gas may be expected places where larg...

Страница 24: ...8k 1 2 12 7 1 4 6 35 7 5 15 30 20 5 8 15 88 1 4 6 35 7 5 15 30 20 5 8 15 88 3 8 9 52 7 5 15 30 30 30k 38k 5 8 15 88 3 8 9 52 7 5 15 30 30 3 4 19 05 3 8 9 52 7 5 15 30 50 If total tubing length becomes...

Страница 25: ...and protect the unit against possible water damage and decreased service life Install cushion rubber under unit s feet to reduce vibration and noise Use lug bolts or equal to bolt down unit reducing...

Страница 26: ...ASRCI EM4H4S09 1854605 1854707 ASRCI EM4H4S12 1854605 1854707 ASRCI EM4H4S18 1854605 1854707 ASRCI EM4H4S24 1854698 1854707 ABSCI EM4H4S09 1854605 1854707 ABSCI EM4H4S12 1854605 1854707 ABSCI EM4H4S18...

Страница 27: ...27 Indoor 1852066 1854605...

Страница 28: ...28 1854698...

Страница 29: ...29 Outdoor 1854707...

Страница 30: ...30 4 3 Refrigerant Flow System NOTE In different models the throttle assembly may be Capillary or Electronic expansion valve...

Страница 31: ...5 Keep evacuating for more than 15mins and make sure the reading of multi meter is 1 0 X105 pa 76cmHg 6 Check the vacuum with the gage manifold valve then close the gage manifold valve and stop the v...

Страница 32: ...ing heating capacity Is heat insulation sufficient It may cause condensation and dripping Is water drainage satisfactory It may cause condensation and dripping Is the voltage in accordance with the ra...

Страница 33: ...is not accurate Operation Test 1 Before Operation Test 1 Do not switch on power before installation is finished completely 2 Electric wiring must be connected correctly and securely 3 Cut off valves...

Страница 34: ...emp Outdoor Air Intake Temp COOLING Maximum 30 46 Minimum 16 16 HEATING Maximum 30 24 Minimum 20 North America SEER 21 Model Temperature Indoor Air Intake Temp Outdoor Air Intake Temp COOLING Maximum...

Страница 35: ...general technical parameters 1 1 Remote receiver distance front of the air conditioner 8 m 1 2 Remote receiver angle Less than 60 degrees 1 3 Temperature control accuracy 1 1 4 Time error Less than 1...

Страница 36: ...you press on the ON OFF button but lost the Air flow direction setting If the appliance was connected to the power at first time it would operate in the auto mode It will keep in stand by state if you...

Страница 37: ...r setting more than 8 hours it will cancel the OFF Timer setting after the Sleep mode OFF 3 When the Sleep mode is select with Cooling mode if the room temperature not less than 26 the setting tempera...

Страница 38: ...the room temperature is not more than 23 it will be operated in the Fan only the air volume is set to LOW and the fan speed can be adjusted After the appliance start the smart operation the setting t...

Страница 39: ...osition it will position at the close position plus 5 3 6 4 4 way valve State It is interrupted in cooling Switchover When initially powered on for cooling the 4 way valve is interrupted immediately W...

Страница 40: ...perature the compressor will be turn off and the air flow change to LOW the louver swing to the Cool air protective position to prevent the air drop into human body directly when the indoor pipe coil...

Страница 41: ...5 4 3 8 4 Outdoor fan The outdoor fan speeds except single speed motor can be changed according to outdoor ambient temperatures 3 7 6 4 way valve State It is electrified in heating Switchover When in...

Страница 42: ...ing area I Operation at the frequency in the range 30 60Hz according to Dt Tindoor ambient Tset Dt f Hz 0 30 0 5 30 1 40 1 5 50 2 60 Dehumidifying area II The compressor stops for 5 minutes and operat...

Страница 43: ...ich may decrease according to situations while cannot rise The outdoor fan runs Condition for the end of anti freezing prohibition of frequency rising state when the temperature of indoor heat exchang...

Страница 44: ...equal to or higher than 14 degrees centigrade EEPROM setting value in the current operating mode Actions of exiting the defrosting state The compressor stops and 50 seconds later the four way valve o...

Страница 45: ...ensor 4 Switch button 5 Feedback from PG motor 6 Up down swing 7 Left right swing 8 Wiring control or wifi interface 9 Display interface 10 Protective tube 1 Interface of PG motor 2 Room temperature s...

Страница 46: ...46 Model of outdoor unit ASRCI4H4S09 ASRCI4H4S12 ABSCI4H4S09 1 Interface of PG motor 2 Room and Pipe temperature sensor 4 Switch button 6 swing 9 Protective tube...

Страница 47: ...47 ASRCI4H4S18 ASRCI4H4S24 ABSCI4H4S12 ABSCI4H4S18...

Страница 48: ...f live wire connect to the terminal panel 2 L 10 Terminal of electronic expansion valve 14 Terminal of compressor overload protector 3 Terminal of reactor 7 cool valve terminal 11 Outdoor ambient temp...

Страница 49: ...mbient temperature sensor 12 Terminal of AC fan 17 Terminal of live wire 3 Terminal of DC fan 8 Outdoor pipe temperature sensor 13 Cool Valve terminal 18 Terminal of neutral 4 Heat Sink temperature se...

Страница 50: ...50 6 2 Fan Motor Drawings attached...

Страница 51: ...ing 0 short circuit or open circuit Test in voltage TOOL Multimeter Insert screwdriver into to rotate indoor fan motor slowly for 1 revolution or over and measure voltage YELLOW and GND on motor The v...

Страница 52: ...r dump motor against hard material Malfunction may not be observed at early stage after such shock But it may be found later this type of mishandling void our warranty Indoor DC Fan Motor Outdoor DC F...

Страница 53: ...0 100 3450 Temperature Resistance k Voltage V Temperature Resistance k Voltage V 20 38 757 0 58143512 31 4 292 2 715076661 19 36 844 0 60795346 32 4 137 2 76063657 18 35 038 0 63530819 33 3 989 2 8055...

Страница 54: ...599135 49 2 286 3 45247766 1 15 683 1 22696435 50 2 211 3 487894953 0 15 1 26865672 51 2 139 3 522585993 1 14 351 1 31098658 52 2 07 3 556485356 2 13 734 1 35393437 53 2 003 3 590032381 3 13 148 1 397...

Страница 55: ...77 0 957 4 210004953 27 4 981 2 52951096 78 0 93 4 228855721 28 4 797 2 57653834 79 0 904 4 247168554 29 4 622 2 62291710 80 0 878 4 265640683 30 4 453 2 66931854 Note the AD value in the table is cal...

Страница 56: ...95 68 10 611 1 952788467 2 206 917 0 15908889 69 10 246 1 994602839 1 196 805 0 16699001 70 9 896 2 036415908 0 187 25 0 17521257 71 9 559 2 078366648 1 177 957 0 18402550 72 9 236 2 120229484 2 169 1...

Страница 57: ...3 066931265 26 55 367 0 54691396 97 4 161 3 10190676 27 52 978 0 56877112 98 4 039 3 13682074 28 50 707 0 59123237 99 3 922 3 171050177 29 48 547 0 61430611 100 3 776 3 214826021 30 46 492 0 63799445...

Страница 58: ...29083 48 22 345 1 16658089 119 2 294 3 738728832 49 21 505 1 20120120 120 2 237 3 762310501 50 20 701 1 23631868 Note the AD value in the table is calculated on the basis of the pull down resistor is...

Страница 59: ...ir conditioner rapidly after removing the plugs Don t place the comp In air for along time 3 Avoiding compressor running in reverse caused by connecting electrical wire incorrectly 4 Warning In case A...

Страница 60: ...oil temperature sensor is failure c the outdoor control board is failure Compressor exhaust temperature sensor in trouble a the compressor exhaust temperature sensor connect loose b the compressor exh...

Страница 61: ...ilure Compressor exhaust temperature too high protection a the compressor exhaust temperature sensor is failure b the refrigerant of the unit is not enough Outdoor ambient temperature sensor in troubl...

Страница 62: ...rty e the air inlet and air outlet of the indoor unit and the outdoor unit is not normally IPM module protection a The IPM board is failure b The outdoor fan is broken c The outdoor fan motor is failu...

Страница 63: ...control panel fails c The measured value of the system pressure exceeds the limit When the compressor is in operation Mark description Light Flash Off the flash cycle is 1S No LED1 LED2 LED3 Reasons f...

Страница 64: ...ard will show the error code automatically when the unit has the following trouble Error code Power Timer Running Sleep Remark Light o Flash x OFF 1 2 3 4 Content Remark The root cause is may be one o...

Страница 65: ...ing 0 Normal 1 x o x x The failure for temperature sensor of outdoor coil a The outdoor temperature sensor loose b The outdoor temperature sensor is failure c The indoor control board is failure 2 Com...

Страница 66: ...power board is failure h the outdoor control board is failure 8 Current overload protection a the fan motor run abnormally b the condensor and evaporator is dirty c the air inlet and outlet is abnorm...

Страница 67: ...o high protection a the compressor exhaust temperature sensor connect loose b the refrigerant of the unit is not enough 16 Anti freeze protection with cooling or overload protection with heating in a...

Страница 68: ...utdoor unit is not normally 22 Compressor pre heating process it is normal mode in cold weather 24 Chip in outdoor board in trouble a Using the wrong drive board b Using the wrong compressor 26 Overhe...

Страница 69: ...oard and the outdoor control board is incorrect or loose d the connection between the filter board and the terminal is incorrect or loose e the indoor control board is failure f the PFC board is failu...

Страница 70: ...rcuit on the jumper terminals to see if the external unit can be started normally or similar method There are two blue terminals on the outdoor control panel as shown above Application Short out the t...

Страница 71: ...ications the compressor and outdoor fan stop but indoor fan runs normally Condition for ending over current protection when the current drops below current value for releasing the refrigeration curren...

Страница 72: ...he temperature of outdoor coiled pipe drops below the anti overload frequency decreasing temperature of outdoor coiled pipe Actions relates to anti overload prohibition of frequency of outdoor coiled...

Страница 73: ...tep one to determine whether the connecting cables and tether cables of indoor outdoor units are correctly wired If not change wiring order and test connection Step two to determine whether there is l...

Страница 74: ...74 Air Con International Inc 1802 SW 2nd St Pompano Beach FL 33069 Tel 954 771 1415 Fax 954 771 1418...

Отзывы: