Display of several measuring points
11.5 Display of several measuring points
The measuring menus described so far are used for selecting and displaying
one meas. point only. In this Chapter we explain how several measuring points
can be displayed at the same time combined with the functions of your choice.
11.5.1 Menu Multi-channel display and bar charts
The menu Multi-channel display ini-
tially shows the measured values of
the first three active channels in
medium size. However, these can be
programmed in numerous ways.
Measuring point
selection
The 1st measuring channel is always the selected measuring point.
This can be selected directly by means of
or
...
To change the other channels, the measuring point
PROG
and
must be selected as function by pressing
or
The selected measuring point can now
be changed by means of
<M
>
,
<M
>
...
To terminate the process of measuring point selection press
<ESC>
To
set the display range
for the bar chart the functions
"analog start"
and
"analog end"
in the
special functions menu
should be used (see 12.4.4). Hav-
ing selected these functions they can be entered by pressing
PROG
and
or
directly on the appropriate axis; (see 10.5).
11.5.2 Differential measurement
If there are two sensors with the same units and same decimal point position
connected at measuring points M0 and M1, the difference M1 - M0 appears au-
tomatically below device-internal measuring point M9 (see 8.2). If the differential
channel is not required, it must be deleted(see 12.3.9). If further differential
channels are needed, these can also be created using the appropriate refer-
ence channels (see 12.4.6).
ALMEMO
®
5690-2M
47
C © REC COM l© ©l R01 * ´´´´´´µµµµ¶
±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±
Time: 12:34:56 Date:01.01.04
01: 25,45 °C
NTC temperature
11
:
54.5 %H
HcrH r. Humidity
21: -12.5 °C
H DT Dew point
M æ M å F ESC
C © REC COM l© ©l R01 * ´´´´´´µµµµ¶
±±±±±±±±±±±±±±±ƒ±±±±±±±±±±±±±±±±±±±±±±
Time: 12:34:56 Date:01.01.04
01: 21.67 °C
Temperatur
|¹¹¹¹¹¹¹¹¸¹¹¹¹¹¹¹¹¸¹¹¹¹¹¹¹¹¸¹¹¹¹¹¹¹¹¸¹¹¹¹¹¹¹¹|¹¹¹¹¹¹¹¹¸¹¹¹¹¹®®®¸®®®®®®®®¸®®®®®®®®¸®®®®®®®®|
10.00 Ntc °C 30.0
11: 7.8 %H
r.Humidity
|¹¹¹¹¹¹¹¹¸¹¹¹¹¹¹¹¹¸¹¹¹¹¹¹¹¹¸¹¹¹¹¹¹®®¸®®®®®®®®|®®®®®®®®®¸®®®®®®®®¸®®®®®®®®¸®®®®®®®®¸®®®®®®®|
0.0 % rH %H 20.0
21: -14.2 °C
Dew point
|¹¹¹¹¹¹¹¹¸¹¹¹¹¹¹¹¹¸¹¹¹¹¹¹®®¸®®®®®®®®¸®®®®®®®®|®®®®®®®®¸®®®®®®®®¸®®®®®®®®¸®®®®®®®®¸®®®®®®®|
-20.0 H DT °C 0.0
31: 1.2 glk
a.Humidity
|¹¹¹¹¹¹¹¹¸¹¹®®®®®®¸®®®®®®®®¸®®®®®®®®¸®®®®®®®®|®®®®®®®®¸®®®®®®®®¸®®®®®®®®¸®®®®®®®®¸®®®®®®®®|
0.0 H AH glk 10.0
START MANU M PRINT ESC
In the menu
Bar charts
the first
four active channels are displayed
with measured value and bar chart.