![Agilent Technologies E4418B Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/agilent-technologies/e4418b/e4418b_user-manual_2868035072.webp)
2
Power Meter Operation
48
E4418B Power Meter User’s Guide
You cannot delete any of the 20 sensor calibration tables. Each sensor
calibration table can contain a maximum of 80 frequency points each. If you
want a new sensor calibration table, you must edit an existing one.
To edit a table:
1
Select one using the
and
keys to scroll through the displayed
tables. When the table you want to edit is highlighted, press
.
The “Edit Cal” screen is displayed as shown in
In this screen, you can modify, add, and remove frequency and
calibration factors and also edit the table name. Use the
,
,
, and
keys to move between the table name and its frequency
and calibration factors.
A frequency in the range of 0.001 MHz to 999.999 GHz can be entered.
A calibration factor in the range of 1% to 150% can be entered.
The following rules apply to naming sensor calibration tables:
•
The name must consist of no more than 12 characters.
•
All characters must be upper or lower case alphabetic characters or
numeric (0- 9) or an underscore (_).
•
No other characters are allowed.
•
No spaces are allowed in the name.
2
To edit the parameter you currently have selected, press
. The
power meter displays the data in a pop- up window. Modify this data (see
below) as desired.
•
Use
or
to modify the character on which the cursor is
currently positioned.
•
Use
or
to move to other characters.
3
To confirm your choice, press the appropriate softkey.
4
To add a new sensor calibration table entry, press
. You are prompted
for the frequency and calibration factor. The entry is sorted by frequency.
N O T E
Predefined sensor calibration factor table stored in power meter is not applicable for
Agilent N8480 Series power sensors with Option CFT. Therefore, users are required to
create a new sensor calibration table for the sensors when a sensor calibration table is
needed.
Edit Table
Change
Insert
Содержание E4418B
Страница 1: ...Agilent Technologies Agilent E4418B Power Meter User s Guide ...
Страница 14: ...xiv E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 20: ...xx E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 22: ...xxii E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 24: ...xxiv E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 47: ...Power Meter Operation 2 E4418B Power Meter User s Guide 23 Contacting Agilent Technologies on page 103 ...
Страница 113: ...Power Meter Operation 2 E4418B Power Meter User s Guide 89 Figure 2 21 Save Recall Screen ...
Страница 126: ...2 Power Meter Operation 102 E4418B Power Meter User s Guide Figure 2 23 Replacing the fuse In line fuse Spare fuse ...
Страница 168: ...3 Menu Reference 144 E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 169: ...145 E4418B Power Meter User s Guide Agilent Technologies 4 Error Messages Introduction 146 Error Messages 148 ...