![Agilent Technologies E4418B Скачать руководство пользователя страница 148](http://html.mh-extra.com/html/agilent-technologies/e4418b/e4418b_user-manual_2868035148.webp)
3
Menu Reference
124
E4418B Power Meter User’s Guide
•
Press this softkey to enter the lower measurement limit. The
measurement units of the limits will be the same as the measurement
units in the currently selected window. On instrument preset, the default
value is either –90.000 dBm, 1 pW, –120 dB, or 100p% depending on the
windows unit. Use the
,
,
, and
keys to change the
value. To confirm your choice, press the appropriate measurement units.
must be less than
.
•
Press this softkey to access a menu which allows you to control the rear
panel TTL outputs. You can:
Switch the TTL outputs on or off.
Set the TTL output level to active high or low.
Determine whether the TTL output represents an over limit condition,
under limit condition or both.
■
Press this softkey to toggle between switching the TTL output off and
on.
■
Press this softkey to select whether the TTL output reflects an
overlimit condition, under limit condition or both.
■
Press this softkey to select whether a high or low level TTL output
represents a limits failure.
Press this key to move through all the softkeys available on a particular level of
a menu. The bottom right of the power meter display indicates the number of
pages in the menu. For example, if “1 of 2” is displayed, pressing
moves
you to “2 of 2”. Pressing
again moves you back to “1 of 2”.
Min
Min
Max
TTL Output
TTL Output Off On
Limits OVER UNDER EITHER
Fail O/P HIGH LOW
Содержание E4418B
Страница 1: ...Agilent Technologies Agilent E4418B Power Meter User s Guide ...
Страница 14: ...xiv E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 20: ...xx E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 22: ...xxii E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 24: ...xxiv E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 47: ...Power Meter Operation 2 E4418B Power Meter User s Guide 23 Contacting Agilent Technologies on page 103 ...
Страница 113: ...Power Meter Operation 2 E4418B Power Meter User s Guide 89 Figure 2 21 Save Recall Screen ...
Страница 126: ...2 Power Meter Operation 102 E4418B Power Meter User s Guide Figure 2 23 Replacing the fuse In line fuse Spare fuse ...
Страница 168: ...3 Menu Reference 144 E4418B Power Meter User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 169: ...145 E4418B Power Meter User s Guide Agilent Technologies 4 Error Messages Introduction 146 Error Messages 148 ...