66
The housings are attached directly on the front panel.
(Fig. 87).
WARNING: Special attention needs to be given to the arrangement of the three LP filtration bowls.
Properly reinstall each element and bowl to the correct housing. Improper sequence can cause damage
to downstream components.
Gas flow input is as follows:
Bowl 1 - HF-7 with sight gauge and auto drain float
Bowl 2 - HF-5 with sight gauge and auto drain float
Bowl 3 - HF-1 no sight gauge or auto drain float
Inspect the filter cartridges as shown:
- Push up on the bottom housing and rotate counter-
clockwise. (Fig. 88);
- Lower the bottom housing off to expose the filter
elements. (Fig. 89);
87
88
89