33
Installation
6.2.2
Connecting the filling hoses
1 Screw hose N° 1 into the special attachment
“A” (Fig. 34) without securing it too tightly
(see point 4).
2 Connect hose N°2 in the same way as described in the previous point.
3 A torque wrench should be available to fasten the hoses.
34
35
4 Tighten the hoses to the machine with a
torque wrench setting of 15Nm (Fig. 35).
NOTE:
- the hoses should be replaced every so often (every year or every 1000 hours) or when they show signs
of being scratched. For this purpose, check the number of operating hours of the hoses that are to be
disconnected (on the hour counter).
- The minimum radius of curvature of each hose must not be less than 250 mm.