43
8.4
High pressure compressor Pilot Valve
50a
MTG
thread
Proceed with the following instructions while
compressor is running (Fig. 50a):
1.
Loosen locknut (4) and back off several
turns. Do not turn differential adjuster (3).
2.
Check reading on the tank pressure gauge
at 12 bar (170 psig). Turn the regulation
screw clockwise to increase pressure or
counterclockwise to decrease pressure.
3.
After pressure is set, tighten locknut (4). Be
careful not to move the nut of threaded
cap (1).
Proceeding with the following instructions while compressor is running:
1. Loosen locknut (2) and back off several turns.
2. Controllare il manometro sul serbatoio.
Check reading on the tank pressure gauge. Set the pressure to 2 bar ( 30 psi) differential (unload at
12 bar - 170 psi, and reload at 10 bar -140 psi). Turn nut (3) clockwise to increase differential pressure
or counterclockwise to decrease differential pressure.
3. After pressure is set, tighten locknut (2). Be careful not to move the nut of threaded
cap (3).
Pressure adjustment
8.4.1
Differential pressure adjustment
8.4.2
SENSING TUBE FROM
AIR RECEIVER
ACTUATING TUBE TO
HEAD UNLOADER
Start up
Содержание MCH 14 TECH NITROX SERIES
Страница 31: ...31 Installation 3 Pass the pipe through the hole located in the rear guard Fig 29 30 28 29 ...
Страница 80: ...80 Troubleshooting 12 1 1 Low pressure compressor ...
Страница 85: ...85 Compression diagram High pressure compressor only air Machine diagrams 14 2 ...
Страница 86: ...86 Machine diagrams 14 3 Electrical diagram ...
Страница 87: ...87 Machine diagrams ...
Страница 100: ...100 153 152 156 155 154 158 097 157 159 160 198 188 187 189 Filtering system High pressure compressor Spare parts ...
Страница 104: ...104 Pulley Crankcase and cylinder Low pressure compressor Spare parts ...
Страница 105: ...105 Piston rod unit Low pressure compressor Spare parts ...
Страница 106: ...106 Cylinder Valve and Filter unit Low pressure compressor Spare parts ...
Страница 107: ...107 Pump unit Low pressure compressor Spare parts ...