STEP 5
When permeate pressure gauge “F” reaches 0,07
bar (1psi) (approximately 3-5 minutes), system
is now ready to be adjusted to the nitrox
percentage level needed for the fill. (Fig. 68).
NOTE: If permeate pressure gauge does not reach (1psi), slightly adjust the LP regulator as follows:
Pull down the bottom of the regulator to unlock.
Then adjust. Clockwise increases pressure;
counter clockwise decreases pressure.
If the psi is lower than 1, adjust the regulator up
slightly. If the psi is higher than 1, lower the
regulator slightly. (Fig. 69).
NOTE: Regulator pressure “D” will never be higher than tank pressure “A”
(Fig. 68).
68
69
Use
Содержание MCH 14 TECH NITROX SERIES
Страница 31: ...31 Installation 3 Pass the pipe through the hole located in the rear guard Fig 29 30 28 29 ...
Страница 80: ...80 Troubleshooting 12 1 1 Low pressure compressor ...
Страница 85: ...85 Compression diagram High pressure compressor only air Machine diagrams 14 2 ...
Страница 86: ...86 Machine diagrams 14 3 Electrical diagram ...
Страница 87: ...87 Machine diagrams ...
Страница 100: ...100 153 152 156 155 154 158 097 157 159 160 198 188 187 189 Filtering system High pressure compressor Spare parts ...
Страница 104: ...104 Pulley Crankcase and cylinder Low pressure compressor Spare parts ...
Страница 105: ...105 Piston rod unit Low pressure compressor Spare parts ...
Страница 106: ...106 Cylinder Valve and Filter unit Low pressure compressor Spare parts ...
Страница 107: ...107 Pump unit Low pressure compressor Spare parts ...